Development of ultrasound‐assisted emulsification microextraction based on solidification of a floating organic droplet for determination of organochlorine pesticides in water samples
Abstract
An ultrasound-assisted emulsification microextraction based on the solidification of a floating organic droplet followed by gas chromatography with electron capture detection was developed for the simultaneous determination of 13 organochlorine pesticides in water samples. In the proposed method, ultrasound was applied to achieve the emulsification without addition of any dispersive solvent. In consequence, the volume of extraction phase remained unaffected by the ion strength of aqueous phase and high extraction recoveries were obtained. It was also found that dilution of the floating phase with acetone was necessary for preventing peak splitting in chromatogram. Under optimal conditions, the proposed method provided good sensitivity (the detection limits of organochlorine pesticides ranged from 1.3 to 3.9 ng/L) and good repeatability of extraction (below 6.5%, n = 5). The recoveries in reservoir and river water samples were between 75.8% and 96.9%.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Organochlorine pesticides are persistent environmental contaminants that were intensively applied in the past.
“Organochlorine pesticides (OCPs) that are persistent environmental contaminants were intensively applied in the past [1 -3].”
The extraction of the investigated OCPs was not affected by pH value.
“Because all the investigated OCPs were very weak acids and bases, their extraction was not a ff ected by pH value, which was con fi rmed by our previous work analyzing OCPs in water sample [2].”
Cites
Cortada, C., Vidal, L., Pastor, R., Santiago, N., & Canals, A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.041 · Cited by 112 · see citing works
Vera-Avila, L. E., Rojo-Portillo, T., Covarrubias-Herrera, R., & Peña-Alvarez, A. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.052 · Cited by 71 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Mansour, F. R., & Danielson, N. D. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.084 · Cited by 178 · see citing works
Ultrasound-assisted extraction of organic contaminants
Albero, B., Tadeo, J. L., & Pérez, R. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.007 · Cited by 120 · see citing works
Modern solutions in the field of microextraction using liquid as a medium of extraction
Płotka-Wasylka, J., Owczarek, K., & Namieśnik, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.08.010 · Cited by 109 · see citing works
Wang, X.-C., Shu, B., Li, S., Yang, Z.-G., & Qiu, B. (2017) · Talanta · doi:10.1016/j.talanta.2016.09.069 · Cited by 91 · see citing works
Self-citation
- Authors
- Shu, B., Yang, Z., Lee, H., Qiu, B., & Li, H.
- Affiliations
- College of Chemistry and Chemical Engineering Central South University Changsha China
- Central South University (CN)
- Corresponding author
- Qiu, Bo
- Li, Haipu
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2016-01-11
- Volume
- 39
- Issue
- 4
- Pages
- 776-783
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2293926288
- Cited by
- 15
- References
- 2
- Citations by year
- 2020: 2 · 2019: 3 · 2018: 3 · 2017: 3 · 2016: 4
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Keywords
- ultrasound-assisted emulsification microextraction, organochlorine pesticides, water samples, reservoir water, river water, gas chromatography with electron capture detection
- MeSH terms
- Chlorine, Chromatography, Gas, Emulsions, Hydrogen-Ion Concentration, Ions, Organic Chemicals, Pesticides, Sensitivity and Specificity, Sodium Chloride, Solvents, Sonication, Ultrasonics, Water, Water Pollutants, Chemical, Water Purification, Rivers, Limit of Detection, Liquid Phase Microextraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review