Preconcentration and determination of 2‐mercaptobenzimidazole by dispersive liquid–liquid microextraction and experimental design
The DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Abstract
A method was developed to determine 2‐mercaptobenzimidazole in water and urine samples using dispersive liquid–liquid microextraction technique coupled with ultraviolet–visible spectrophotometry. It was essential to peruse the effect of all parameters that can likely influence the performance of extraction. The influence of parameters, such as dispersive and extraction solvent volume and sample volume, on dispersive liquid–liquid microextraction was studied. The optimization was carried out by the central composite design method. The central composite design optimization method resulted in 1.10 mL dispersive solvent, 138.46 μL extraction solvent, and 4.46 mL sample volume. Under the optimal terms, the calibration curve was linear over the range of 0.003–0.18 and 0.007–0.18 μg/mL in water and urine samples, respectively. The limit of detection and quantification of the proposed approach for 2‐mercaptobenzimidazole were 0.013 and 0.044 μg/mL in water samples and 0.016 and 0.052 μg/mL in urine samples, respectively. The method was successfully applied to determination of 2‐mercaptobenzimidazole in urine and water samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“DLLME has advantages such as high efficiency, simple operation, and low consumption of extraction and dispersion solvents [12].”
From Thermo‐Assisted Deep Eutectic Solvent Based on Dispersive Liquid‐Liquid Microextraction for Preconcentration of Phthalate Esters in Water Samples and Determination by Gas Chromatography With Flame Ionization Detection (2024) · cites this paper as [12]
Experimental — accuracy not yet measured
Citations
Cites
Response surface methodology (RSM) as a tool for optimization in analytical chemistry
Bezerra, M. A., Santelli, R. E., Oliveira, E. P., Villar, L. S., & Escaleira, L. A. (2008) · Talanta · doi:10.1016/j.talanta.2008.05.019 · Cited by 6,075
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 1×
“This method with unique advantages such as simplicity of operation, rapidity, low extraction time, high recovery and enrichment factor has been widely used for the drug analysis [26], which was successfully used for the extraction and determination of polycyclic aromatic hydrocarbons [27], organophosphorus pesticides…”
Zeini Jahromi, E., Bidari, A., Assadi, Y., Milani Hosseini, M. R., & Jamali, M. R. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.01.007 · Cited by 398
Zare-Dorabei, R., Ferdowsi, S. M., Barzin, A., & Tadjarodi, A. (2016) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2016.03.020 · Cited by 247
Developments of Dispersive Liquid-Liquid Microextraction Technique
ZANG, X.-H., WU, Q.-H., ZHANG, M.-Y., XI, G.-H., & WANG, Z. (2009) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(08)60082-1 · Cited by 198
Saghanejhad Tehrani, M., & Zare-Dorabei, R. (2016) · RSC Advances · doi:10.1039/c5ra28052d · Cited by 168
Rezaei, F., Bidari, A., Birjandi, A. P., Milani Hosseini, M. R., & Assadi, Y. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.02.005 · Cited by 164 · cited 1×
“Extraction and preconcentration techniques, such as LLE, SPE, and SPME are widely applied to determine drug in different samples [18].”
Tehrani, M. S., & Zare‐Dorabei, R. (2016) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2016.02.002 · Cited by 152
Tadjarodi, A., Moazen Ferdowsi, S., Zare-Dorabei, R., & Barzin, A. (2016) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2016.04.030 · Cited by 141
Khodadoust, S., & Ghaedi, M. (2013) · Journal of Separation Science · doi:10.1002/jssc.201300085 · Cited by 102
Research works printed but not linked: 1
- Brabander H. F., 1992, Determination of thyreostatic drugs by HPTLC with confirmation by GC–MS, J. Planar. Chromatogr., 5, 124
Cited by
Miniaturization of Liquid-Liquid extraction; the barriers and the enablers
Kannouma, R. E., Hammad, M. A., Kamal, A. H., & Mansour, F. R. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.107863 · Cited by 92
Recent applications of microextraction sample preparation techniques in biological samples analysis
Daryanavard, S. M., Zolfaghari, H., Abdel‐Rehim, A., & Abdel‐Rehim, M. (2021) · Biomedical Chromatography · doi:10.1002/bmc.5105 · Cited by 52
Shen, X., Liang, J., Zheng, L., Lv, Q., & Wang, H. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700722 · Cited by 33
Wang, Y., Li, H., Yang, Z., Zhang, W., & Hua, J. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700744 · Cited by 16
Pourbasheer, E., Malekpour, L., Azari, Z., Masand, V. H., & Ganjali, M. R. (2023) · Scientific Reports · doi:10.1038/s41598-023-30404-6 · Cited by 9
Self-citationAbdi, K., Ezoddin, M., Novasari, V., & Lamei, N. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300878 · Cited by 6
Witek, S., Woźniak, B., Matraszek-Żuchowska, I., & Posyniak, A. (2017) · Journal of Separation Science · doi:10.1002/jssc.201701069 · Cited by 4
Evaluation and Optimization of a New Approach on Phenol Extraction from Real Water
Wee, N. N. A. N., Juber, N. I. M., Norrrahim, M. N. F., & Saleh, N. M. (2020) · Sains Malaysiana · doi:10.17576/jsm-2020-4910-13 · Cited by 4
“According to Pourbasheer et al. (2017) and Rezaee et al. (2006), increasing in salt concentration will reduce the solubility of the extraction solvent due to the presence of salt in the mixture.”
BackgroundIsalou, A., Pourbasheer, E., Beheshti, A., & Ganjali, M. R. (2023) · Journal of Analytical Chemistry · doi:10.1134/s1061934823010069 · Cited by 2
Self-citationAzari, Z., Pourbasheer, E., Bahar, S., Abdolmohammad‐Zadeh, H., & Ganjali, M. R. (2022) · ChemistrySelect · doi:10.1002/slct.202104570 · Cited by 1
Self-citation
Metadata
- Authors
- Pourbasheer, E., Qasemi, F., Rouhi, M., Azari, Z., & Ganjali, M. R.
- Affiliations
- Payame Noor University (IR)
- University of Tehran (IR)
- Corresponding author
- Pourbasheer, Eslam
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2017-06
- Volume
- 40
- Issue
- 11
- Pages
- 2467-2473
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2607211663
- Cited by
- 10
- References
- 43
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 1 · 2017: 3
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Keywords
- 2-mercaptobenzimidazole, dispersive liquid-liquid microextraction, preconcentration, central composite design, extraction optimization, water samples, urine samples, UV-Vis spectroscopy, thiols
- MeSH terms
- Benzimidazoles, Chromatography, High Pressure Liquid, Humans, Liquid Phase Microextraction, Drinking Water
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.