Determination of vitamin A in blood serum based on solid-phase extraction using cetyltrimethyl ammonium bromide-modified attapulgite
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Cetyltrimethyl ammonium bromide‐modified attapulgite was prepared and utilized as a novel sorbent in a simple solid‐phase extraction method for the determination of vitamin A in blood serum. Several factors affecting extraction efficiency were systematically optimized, including the sampling solvent and its volume, as well as the elution solvent and its volume. Under the optimal solid‐phase extraction conditions, the adsorption capacity of vitamin A was as high as 28 mg/g according to the Langmuir isotherm model. Based on the developed solid‐phase extraction method, the level of vitamin A in 200 µL blood serum sample could be accurately determined by high‐performance liquid chromatography. The recoveries of vitamin A spiked in 10% v/v methanol aqueous solutions were in the range of 86.9–92.8%, with the relative standard deviations not more than 8.1%. The method was applied to the determination of vitamin A in serum samples from 20 pregnant women. Compared with the previously reported solid‐phase extraction methods for determination of vitamin A in serum, our developed cetyltrimethyl ammonium bromide‐modified attapulgite‐based solid‐phase extraction method used lower serum volume, omitted extra steps (i.e. evaporation and re‐dissolution), and eliminated internal standard. The results were promising for it to be used in routine monitoring during pregnancy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In fact, concentrations of endogenous ATRA in tissues are up to several orders of magnitude below the limit of detection and/or limit of quantification for both DAD and single-wavelength detection [279,280,281,282,283,284,285,286,287,288,289,290,291,292,293,294,295,320,321,322,323,324].”
From Vitamin A Update: Forms, Sources, Kinetics, Detection, Function, Deficiency, Therapeutic Use and Toxicity (2021) · cites this paper as [285]
Citations
Cites
Shrivastava, A., & Gupta, V. (2011) · Chronicles of Young Scientists · doi:10.4103/2229-5186.79345 · Cited by 3,205
Selective adsorption of tannin from flavonoids by organically modified attapulgite clay
Huang, J., Liu, Y., & Wang, X. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.03.008 · Cited by 164
Heudi, O., Trisconi, M.-J., & Blake, C.-J. (2003) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.09.062 · Cited by 145
Su, R., Wang, X., Xu, X., Wang, Z., Li, D., Zhao, X., Li, X., Zhang, H., & Yu, A. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.05.088 · Cited by 75
Self-citationChen, Y., Lin, Z., Hao, R., Xu, H., & Huang, C. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.02.096 · Cited by 70
Self-citationGranado‐Lorencio, F., Herrero-Barbudo, C., Blanco-Navarro, I., & Pérez-Sacristán, B. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3655-2 · Cited by 69
Sorption of p-nitrophenol by anion–cation modified palygorskite
Chang, Y., Lv, X., Zha, F., Wang, Y., & Lei, Z. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.02.105 · Cited by 61
Urbánek, L., Solichová, D., Melichar, B., Dvořák, J., Svobodová, I., & Solich, P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.02.032 · Cited by 61
Cui, X., Zhang, P., Yang, X., Yang, M., Zhou, W., Zhang, S., Gao, H., & Lu, R. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.03.056 · Cited by 47
Mata-Granados, J. M., Luque de Castro, M. D., & Quesada, J. M. (2004) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2004.01.027 · Cited by 45
Gundersen, T. E., Lundanes, E., & Blomhoff, R. (1997) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(96)00434-3 · Cited by 44
Khaksari, M., Mazzoleni, L. R., Ruan, C., Kennedy, R. T., & Minerick, A. R. (2017) · Experimental Eye Research · doi:10.1016/j.exer.2016.12.007 · Cited by 42
Xue, X., You, J., & He, P. (2008) · Journal of Chromatographic Science · doi:10.1093/chromsci/46.4.345 · Cited by 41
Mata-Granados, J. M., Gómez, J. M., & de Castro, M. D. L. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.029 · Cited by 37
Wang, T., Chen, Y., Ma, J., Jin, Z., Chai, M., Xiao, X., Zhang, L., & Zhang, Y. (2017) · Talanta · doi:10.1016/j.talanta.2017.12.059 · Cited by 35
Self-citationSynthesis of Water‐Soluble Retinol Derivatives by Enzymatic Method
Maugard, T., Réjasse, B., & Legoy, M. D. (2002) · Biotechnology Progress · doi:10.1021/bp025508f · Cited by 29
Wang, T., Zhu, Y., Ma, J., Xuan, R., Gao, H., Liang, Z., Zhang, L., & Zhang, Y. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400900 · Cited by 28
Self-citationYang, X., Lin, X., Mi, Y., Gao, H., Li, J., Zhang, S., Zhou, W., & Lu, R. (2018) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.04.043 · Cited by 27
Maia, S. B., Caminha, M. D. F. C., da Silva, S. L., Souza, A. S. R., dos Santos, C. C., & Filho, M. B. (2018) · Nutrients · doi:10.3390/nu10091271 · Cited by 26
Wang, T., Xuan, R., Ma, J., Tan, Y. S., Jin, Z., Chen, Y., Zhang, L., & Zhang, Y. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9779-2 · Cited by 25
Self-citationHinchliffe, E., Rudge, J., & Reed, P. (2015) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215596024 · Cited by 23
Červinková, B., Krčmová, L. K., Klabackova, S., Solichová, D., & Solich, P. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700492 · Cited by 20
Arafa, H. M. M., Hamada, F. M., Elmazar, M. M., & Nau, H. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00980-9 · Cited by 19
Chai, M., Chen, Y., Xuan, R., Ma, J., Jin, Z., Wang, T., Qiu, D., Zhang, L., & Zhang, Y. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1271-8 · Cited by 18
Self-citationChu, G., Cai, W., & Shao, X. (2015) · Talanta · doi:10.1016/j.talanta.2014.12.051 · Cited by 16
Bunkoed, O., Rueankaew, T., Nurerk, P., & Kanatharana, P. (2016) · Journal of Separation Science · doi:10.1002/jssc.201600285 · Cited by 13
Chase, G. W., Ye, L., Stoakes, V. C., Eitenmiller, R. R., & Long, A. R. (2004) · Journal of AOAC International · doi:10.1093/jaoac/87.5.1173 · Cited by 13
Fedder, R., & Plöger, A. (2005) · Journal of AOAC International · doi:10.1093/jaoac/88.6.1579 · Cited by 7
Iwase, H. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00608-3 · Cited by 6
Cited by
Carazo, A., Macáková, K., Matoušová, K., Krčmová, L. K., Protti, M., & Mladěnka, P. (2021) · Nutrients · doi:10.3390/nu13051703 · Cited by 461
Köseoğlu, K., Ulusoy, H. İ., Yılmaz, E., & Soylak, M. (2020) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2020.103482 · Cited by 42
Li, X., Chen, Y., Chen, S., Hou, C., Xuan, R., Gao, Y., Ren, S., Yao, L., Wang, T., Zhang, L., et al. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03304-9 · Cited by 23
Self-citationDong, L., Chen, Y., Chen, S., Hou, C., Wang, S., Xuan, R., Fang, K., Wang, T., Zhang, L., & Zhang, Y. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03155-4 · Cited by 18
Self-citationEl-Din, S. H. S., Mahmoud, A. M., & Morsy, A. R. (2025) · BMC Chemistry · doi:10.1186/s13065-025-01441-1 · Cited by 8
Metadata
- Authors
- Xuan, R., Wang, T., Hou, C., Li, X., Li, Y., Chen, Y., Gao, Y., Qiu, D., Xiao, X., Zhang, L., & Zhang, Y.
- Affiliations
- Ningbo University (CN)
- Ningbo University of Technology (CN)
- Dalian Institute of Chemical Physics (CN)
- Ningbo Entry-Exit Inspection And Quarantine Bureau (CN)
- Corresponding author
- Wang, Tingting
- Xiao, Xunwen
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2019-10-10
- Volume
- 42
- Issue
- 23
- Pages
- 3521-3527
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2974934580
- Cited by
- 8
- References
- 29
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 1 · 2021: 3 · 2020: 2
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Zhejiang Province Public Welfare Technology Application Research Project (LGC19B050004, LGN18B060002)
- National Natural Science Foundation of China (21405085)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Keywords
- vitamin A, serum, solid-phase extraction, cetyltrimethylammonium bromide, attapulgite, modified sorbents, pregnant women, pregnancy monitoring, vitamin A levels, Langmuir isotherm, extraction optimization
- MeSH terms
- Cetrimonium, Adsorption, Chromatography, High Pressure Liquid, Female, Humans, Pregnancy, Vitamin A, Magnesium Compounds, Silicon Compounds, Serum, Solid Phase Extraction, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.