CoChat

Determination of vitamin A in blood serum based on solid-phase extraction using cetyltrimethyl ammonium bromide-modified attapulgite

Xuan, Rongrong, Wang, Tingting, Hou, Chunyan, Li, Xie, Li, Ying, Chen, Yihui, Gao, Yajie, Qiu, Dan, Xiao, Xunwen, Zhang, Lihua, Zhang, Yukui · 2019 · Journal of Separation Science

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Cetyltrimethyl ammonium bromide‐modified attapulgite was prepared and utilized as a novel sorbent in a simple solid‐phase extraction method for the determination of vitamin A in blood serum. Several factors affecting extraction efficiency were systematically optimized, including the sampling solvent and its volume, as well as the elution solvent and its volume. Under the optimal solid‐phase extraction conditions, the adsorption capacity of vitamin A was as high as 28 mg/g according to the Langmuir isotherm model. Based on the developed solid‐phase extraction method, the level of vitamin A in 200 µL blood serum sample could be accurately determined by high‐performance liquid chromatography. The recoveries of vitamin A spiked in 10% v/v methanol aqueous solutions were in the range of 86.9–92.8%, with the relative standard deviations not more than 8.1%. The method was applied to the determination of vitamin A in serum samples from 20 pregnant women. Compared with the previously reported solid‐phase extraction methods for determination of vitamin A in serum, our developed cetyltrimethyl ammonium bromide‐modified attapulgite‐based solid‐phase extraction method used lower serum volume, omitted extra steps (i.e. evaporation and re‐dissolution), and eliminated internal standard. The results were promising for it to be used in routine monitoring during pregnancy.

Overview

Integrity signals

Registry

Crossref · 10.1002/jssc.201900778

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 29 references

Cited by

See all 8

Metadata

Authors
Xuan, R., Wang, T., Hou, C., Li, X., Li, Y., Chen, Y., Gao, Y., Qiu, D., Xiao, X., Zhang, L., & Zhang, Y.
Affiliations
  • Ningbo University (CN)
  • Ningbo University of Technology (CN)
  • Dalian Institute of Chemical Physics (CN)
  • Ningbo Entry-Exit Inspection And Quarantine Bureau (CN)
Corresponding author
  • Wang, Tingting
  • Xiao, Xunwen
Venue
Journal of Separation Science
Publisher
Wiley
Published
2019-10-10
Volume
42
Issue
23
Pages
3521-3527
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2974934580
Cited by
8
References
29
Citations by year
2025: 1 · 2024: 1 · 2022: 1 · 2021: 3 · 2020: 2
FWCI
0.84
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Zhejiang Province Public Welfare Technology Application Research Project (LGC19B050004, LGN18B060002)
  • National Natural Science Foundation of China (21405085)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
Keywords
vitamin A, serum, solid-phase extraction, cetyltrimethylammonium bromide, attapulgite, modified sorbents, pregnant women, pregnancy monitoring, vitamin A levels, Langmuir isotherm, extraction optimization
MeSH terms
Cetrimonium, Adsorption, Chromatography, High Pressure Liquid, Female, Humans, Pregnancy, Vitamin A, Magnesium Compounds, Silicon Compounds, Serum, Solid Phase Extraction, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.