Synthesis and characterization of pH‐responsive deep eutectic solvent followed by HPLC for trace determination of bisphenol A in water samples
Abstract
A microextraction based on pH‐responsive deep eutectic solvent combined with high‐performance liquid chromatography was developed for the separation, preconcentration, and determination of bisphenol A in water samples. Five deep eutectic solvents were prepared using thymol (hydrogen bond acceptor) and 6‐, 8‐, 9‐, 10‐, and 12‐carbon carboxylic acids (hydrogen bond donor), and were used as extraction solvent. Herein, by alkalinizing the environment, phase transition takes place, and by adding acid, phase separation and extraction of analytes occur simultaneously. Some important parameters on the extraction such as deep eutectic solvent type, molar ratio of deep eutectic solvent components, deep eutectic solvent volume, potassium hydroxide concentration, hydrochloric acid volume, extraction time, and salt addition were optimized. Under the optimum conditions, intra‐ and interday precisions of the method based on seven replicate measurements of 10 μg L –1 of bisphenol A in water samples were 2.2% and 4.3%, respectively. The analytical performance of the method showed linearity over the concentration of 0.05–50 μg L −1 with the detection limit of 0.02 μg L −1 . The accuracy of the method was confirmed by spiking different concentrations of bisphenol A in real water samples and obtaining relative recoveries in the range of 92.5%−105.2%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
EFSA Panel on Food Contact Materials, E. (2015) · EFSA Journal · doi:10.2903/j.efsa.2015.3978 · Cited by 1,023
Analytical methods for the determination of bisphenol A in food
Ballesteros-Gómez, A., Rubio, S., & Pérez-Bendito, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.06.037 · Cited by 407
Rezaee, M., Yamini, Y., Shariati, S., Esrafili, A., & Shamsipur, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.091 · Cited by 336
Caballero-Casero, N., Lunar, L., & Rubio, S. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.034 · Cited by 208
López-Darias, J., Germán-Hernández, M., Pino, V., & Afonso, A. M. (2010) · Talanta · doi:10.1016/j.talanta.2009.09.057 · Cited by 142
Balaram, V., Copia, L., Kumar, U. S., et al. (2023) · Geosystems and Geoenvironment · doi:10.1016/j.geogeo.2023.100210 · Cited by 120
Wu, X. G., Li, Y., Zhu, X., He, C., Wang, Q., & Liu, S. (2016) · Talanta · doi:10.1016/j.talanta.2016.10.007 · Cited by 111
Self-citationTaghizadeh, T., Talebian‐Kiakalaieh, A., Jahandar, H., et al. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121950 · Cited by 102
Hydrophobic deep eutectic solvents for purification of water contaminated with Bisphenol-A
Florindo, C., Monteiro, N. V., Ribeiro, B. D., Branco, L. C., & Marrucho, I. M. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.111841 · Cited by 93
Kawaguchi, M., Ito, R., Endo, N., Okanouchi, N., Sakui, N., Saito, K., & Nakazawa, H. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.01.061 · Cited by 87
Cited by
Responsive deep eutectic solvents: mechanisms, applications and their role in sustainable chemistry
Vicente, F. A., Tkalec, N., & Likozar, B. (2024) · Chemical Communications · doi:10.1039/d4cc05157b · Cited by 60
Rafati, S., Ebrahimi, N., & Sadeghi, R. (2024) · Separation and Purification Technology · doi:10.1016/j.seppur.2024.130583 · Cited by 23
Kumar, S., Satapathy, S., Kurmi, B. D., Gupta, G. D., & Patel, P. (2024) · Separation Science Plus · doi:10.1002/sscp.202400018 · Cited by 17
Godunov, P., Gerasimova, A., Shishov, A. Y., & Bulatov, A. V. (2024) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2024.106569 · Cited by 17
Wu, Y., Gu, Z., Wei, W., Xu, R., Qian, Y. J., & Wang, X. (2025) · Separation and Purification Technology · doi:10.1016/j.seppur.2025.132024 · Cited by 10
Ataee, M., Jouybari, T. A., Jouybari, H. A., Hosseini, F., & Fattahi, N. (2024) · Separation Science Plus · doi:10.1002/sscp.202400123 · Cited by 9
AlSalem, H. S., Alharbi, S. N., Abdel-Lateef, M. A.-K., et al. (2025) · Talanta Open · doi:10.1016/j.talo.2025.100587 · Cited by 7
Chen, J., Bae, B., & Lee, J. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118547 · Cited by 8
Abdi, K., Ezoddin, M., Novasari, V., & Lamei, N. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300878 · Cited by 6
Rubio, I., Rayos, J., Ortega, I., Aguirre, M. Á., Vidal, L., & Canals, A. (2026) · Talanta · doi:10.1016/j.talanta.2026.129430 · Cited by 3
Schincaglia, A., Cavazzini, A., Pasti, L., Purcaro, G., & Beccaria, M. (2025) · Green Analytical Chemistry · doi:10.1016/j.greeac.2025.100220 · Cited by 2
Elbitar, F. S., Hussein, L. A. E.-A., Zahar, N. M. E., Yamani, H. Z., & Mansour, F. R. (2026) · BMC Chemistry · doi:10.1186/s13065-025-01713-w · Cited by 5
“Thymol-based, pH-responsive DESs prepared with medium-chain carboxylic acids have shown excellent extractive capability for BPA through reversible, stimulus-controlled phase transitions, achieving high sensitivity and recovery in water samples [30].”
Abdel‐Monem, M. M., Eid, M., Aly, F. A., & Abdallah, N. A. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118475 · Cited by 3
Use of unconventional solvents for sample preparation in environmental analysis
Ražić, S., Arsenijević, J., Trtić‐Petrović, T. M., Meng, Y., & Anderson, J. L. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00036-9 · Cited by 2
Carotti, C., Righetti, G. I. C., Mannu, A., Rossetti, A., Riva, L., Nicastro, G., Vangosa, F. B., Punta, C., Mele, A., & Pietro, M. E. D. (2025) · ACS Omega · doi:10.1021/acsomega.5c07390 · Cited by 5
Fattahi, N., Zohrabi, P., Karimi, P., Sosa, F. H. B., Hashemi, B., & Shiri, F. (2026) · Journal of Chromatography A · doi:10.1016/j.chroma.2026.466709 · Cited by 1
Lu, W., Ma, L., Cademartiri, L., Zhang, B., Li, Y., Ren, Q., Dai, S., Zhang, Q., & Han, B. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.172808 · Cited by 1
Self-citationPaz, R., Viltres, H., Gupta, N. K., et al. (2026) · Analytical Methods · doi:10.1039/d6ay01231k
Metadata
- Authors
- Cao, L., & Li, Y.
- Affiliations
- Heilongjiang Bayi Agricultural University (CN)
- Corresponding author
- Cao, Lili
- ORCID
- Cao, Lili
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2023-12-08
- Volume
- 47
- Issue
- 1
- Pages
- e2300776-e2300776
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W4389508864
- Semantic Scholar
- 83192070751b5d8b75be2ac2a9ec2a76f582cf42
- Cited by
- 20
- References
- 43
- Citations by year
- 2026: 8 · 2025: 5 · 2024: 7
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Heilongjiang Bayi Agricultural University
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Chemical Engineering › Filtration and Separation › Chemical and Physical Properties in Aqueous Solutions
- Keywords
- bisphenol A, deep eutectic solvents, thymol, carboxylic acids, solid-phase microextraction, preconcentration, water samples, trace determination, phase transitions, alkalization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.