CoChat

Automatic Recognition of Laryngoscopic Images Using a Deep‐Learning Technique

Open access
Ren, Jianjun, Jing, Xueping, Wang, Jing, Ren, Xue, Xu, Yang, Yang, Qiuyun, Ma, Lanzhi, Sun, Yi, Xu, Wei, Yang, Ning, Zou, Jian, Zheng, Yongbo, Chen, Min, Gan, Weigang, Xiang, Ting, An, Junnan, Liu, Ruiqing, Lv, Cao, Lin, Ken, Zheng, Xianfeng, Lou, Fan, Rao, Yufang, Yang, Hui, Liu, Kai, Liu, Geoffrey, Lu, Tao, Zheng, Xiujuan, Zhao, Yu · 2020 · The Laryngoscope
Cited by 134

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Objectives/Hypothesis: To develop a deep‐learning–based computer‐aided diagnosis system for distinguishing laryngeal neoplasms (benign, precancerous lesions, and cancer) and improve the clinician‐based accuracy of diagnostic assessments of laryngoscopy findings. Study Design: Retrospective study. Methods: A total of 24,667 laryngoscopy images (normal, vocal nodule, polyps, leukoplakia and malignancy) were collected to develop and test a convolutional neural network (CNN)‐based classifier. A comparison between the proposed CNN‐based classifier and the clinical visual assessments (CVAs) by 12 otolaryngologists was conducted. Results: In the independent testing dataset, an overall accuracy of 96.24% was achieved; for leukoplakia, benign, malignancy, normal, and vocal nodule, the sensitivity and specificity were 92.8% vs. 98.9%, 97% vs. 99.7%, 89% vs. 99.3%, 99.0% vs. 99.4%, and 97.2% vs. 99.1%, respectively. Furthermore, when compared with CVAs on the randomly selected test dataset, the CNN‐based classifier outperformed physicians for most laryngeal conditions, with striking improvements in the ability to distinguish nodules (98% vs. 45%, P < .001), polyps (91% vs. 86%, P < .001), leukoplakia (91% vs. 65%, P < .001), and malignancy (90% vs. 54%, P < .001). Conclusions: The CNN‐based classifier can provide a valuable reference for the diagnosis of laryngeal neoplasms during laryngoscopy, especially for distinguishing benign, precancerous, and cancer lesions. Level of Evidence: NA Laryngoscope, 130:E686–E693, 2020

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lary.28539

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 134

Metadata

Authors
Ren, J., Jing, X., Wang, J., Ren, X., Xu, Y., Yang, Q., Ma, L., Sun, Y., Xu, W., Yang, N., Zou, J., Zheng, Y., Chen, M., Gan, W., Xiang, T., An, J., Liu, R., Lv, C., Lin, K., Zheng, X., Lou, F., Rao, Y., Yang, H., Liu, K., Liu, G., Lu, T., Zheng, X., & Zhao, Y.
Venue
The Laryngoscope
Publisher
Wiley
Published
2020-02-18
Volume
130
Issue
11
Pages
E686-E693
ISSN
  • 0023-852X (ISSN-L)
  • 1531-4995
OpenAlex
W3006805607
Cited by
134
References
10
FWCI
6.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic Recognition of Laryngoscopic Images Using a Deep‐Learning Technique. https://app.cochat.ai/papers/10.1002/lary.28539
The paper
Ren, J., Jing, X., Wang, J., Ren, X., Xu, Y., Yang, Q., Ma, L., Sun, Y., Xu, W., Yang, N., Zou, J., Zheng, Y., Chen, M., Gan, W., Xiang, T., An, J., Liu, R., Lv, C., Lin, K., . . . Zhao, Y. (2020). Automatic Recognition of Laryngoscopic Images Using a Deep‐Learning Technique. The Laryngoscope. https://doi.org/10.1002/lary.28539

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.