The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Spectroscopic diagnosis of bladder cancer with elastic light scattering
Abstract
Background and Objectives: Recently, significant progress has been made toward the development of optical, noninvasive medical diagnostics. The goal of this study was to evaluate elastic scatter measurements as a tool for diagnosing bladder cancer. Study Design/Materials and Methods: In vivo measurements on 10 patients with suspected bladder cancer were made with the optical biopsy system (OBS) developed at Los Alamos National Laboratory. Elastic‐scatter spectra over the wavelength range 250–800 nm were obtained using a fiber‐optic probe through one of the lumens of a urological cystoscope. Measurements were made on putatively normal areas and areas of uncertain abnormality, as well as those suspected to be cancerous. After measurements were made with the OBS, biopsy samples were taken at the measurement sites. Comparisons of the histopathology and the optical spectra were then made. Results and Conclusions: A diagnostic algorithm for distinguishing malignant from nonmalignant tissue based on the values of the slopes over the wavelength range 330–370 nm has a sensitivity of 100% and specificity of 97% for the limited number of patients in this Study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Self-citationDiffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Van Dam, J., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 534
Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
Self-citationIn vivo local determination of tissue optical properties: applications to human brain
Bevilacqua, F., Piguet, D., Marquet, P., Gross, J. D., Tromberg, B. J., & Depeursinge, C. (1999) · Applied Optics · doi:10.1364/ao.38.004939 · Cited by 456
Metadata
- Authors
- Mourant, J. R., Bigio, I. J., Boyer, J., Conn, R. L., Johnson, T., & Shimada, T.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 17
- Issue
- 4
- Pages
- 350-357
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2075432345
- Cited by
- 250
- References
- 1
- FWCI
- 8.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.