The DOI matches its Crossref record.
Ex vivo histological characterization of a novel ablative fractional resurfacing device
Open accessAbstract
Background and Objectives: We introduce a novel CO 2 laser device that utilizes ablative fractional resurfacing for deep dermal tissue removal and characterize the resultant thermal effects in skin. Study Design/Materials and Methods: A prototype 30 W, 10.6 µm CO 2 laser was focused to a 1/e 2 spot size of 120 µm and pulse duration up to 0.7 milliseconds to achieve a microarray pattern in ex vivo human skin. Lesion depth and width were assessed histologically using either hematoxylin & eosin (H&E) or lactate dehyrdogenase (LDH) stain. Pulse energies were varied to determine their effect on lesion dimensions. Results: Microarrays of ablative and thermal injury were created in fresh ex vivo human skin irradiated with the prototype CO 2 laser device. Zones of tissue ablation were surrounded by areas of tissue coagulation spanning the epidermis and part of the dermis. A thin condensed lining on the interior wall of the lesion cavity was observed consistent with eschar formation. At 23.3 mJ, the lesion width was approximately 350 µm and depth 1 mm. In this configuration, the cavities were spaced approximately 500 µm apart and interlesional epidermis and dermis demonstrated viable tissue by LDH staining. Conclusion: A novel prototype ablative CO 2 laser device operating in a fractional mode was developed and its resultant thermal effects in human abdominal tissue were characterized. We discovered that controlled microarray patterns could be deposited in skin with variable depths of dermal tissue ablation depending on the treatment pulse energy. This is the first report to characterize the successful use of ablative fractional resurfacing as a potential approach to dermatological treatment. Lasers Surg. Med. 39:87–95, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular Mechanisms of Dermal Aging and Antiaging Approaches
Shin, J.-W., Kwon, S.-H., Choi, J.-Y., Na, J.-I., Huh, C.-H., Choi, H.-R., & Park, K.-C. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20092126 · Cited by 875
Acne Scars: Pathogenesis, Classification and Treatment
Fabbrocini, G., Annunziata, M. C., D′Arco, V., De Vita, V., Lodi, G., Mauriello, M. C., Pastore, F., & Monfrecola, G. (2010) · Dermatology Research and Practice · doi:10.1155/2010/893080 · Cited by 440
In vivo histological evaluation of a novel ablative fractional resurfacing device
Hantash, B. M., Bedi, V. P., Kapadia, B., Rahman, Z., Jiang, K., Tanner, H., Chan, K. F., & Zachary, C. B. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20468 · Cited by 424
Self-citationSuccessful treatment of acneiform scarring with CO2ablative fractional resurfacing
Chapas, A. M., Brightman, L., Sukal, S., Hale, E., Daniel, D., Bernstein, L. J., & Geronemus, R. G. (2008) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20659 · Cited by 284
Fractional CO2 laser‐assisted drug delivery
Hædersdal, M., Sakamoto, F. H., Farinelli, W. A., Doukas, A. G., Tam, J., & Anderson, R. R. (2010) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20860 · Cited by 273
Metadata
- Authors
- Hantash, B. M., Bedi, V. P., Chan, K. F., & Zachary, C. B.
- Venue
- Lasers in Surgery and Medicine
- Publisher
- Wiley
- Published
- 2006-11-17
- Volume
- 39
- Issue
- 2
- Pages
- 87-95
- ISSN
- 0196-8092 (ISSN-L)
- 1096-9101
- OpenAlex
- W2108675826
- Cited by
- 232
- References
- 0
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ex vivo histological characterization of a novel ablative fractional resurfacing device. https://app.cochat.ai/papers/10.1002/lsm.20405
- The paper
- Hantash, B. M., Bedi, V. P., Chan, K. F., & Zachary, C. B. (2007). Ex vivo histological characterization of a novel ablative fractional resurfacing device. Lasers in Surgery and Medicine. https://doi.org/10.1002/lsm.20405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.