Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 218

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

In vivo nonmelanoma skin cancer diagnosis using Raman microspectroscopy

Open access
Lieber, Chad A., Majumder, Shovan K., Ellis, Darrel L., Billheimer, D. Dean, Mahadevan‐Jansen, Anita · 2008 · Lasers in Surgery and Medicine

Abstract

Background and Objectives: Nonmelanoma skin cancers, including basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), are the most common skin cancers, presenting nearly as many cases as all other cancers combined. The current gold‐standard for clinical diagnosis of these lesions is histopathologic examination, an invasive, time‐consuming procedure. There is thus considerable interest in developing a real‐time, automated, noninvasive tool for nonmelanoma skin cancer diagnosis. In this study, we explored the capability of Raman microspectroscopy to provide differential diagnosis of BCC, SCC, inflamed scar tissue, and normal tissue in vivo. Study Design: Based on the results of previous in vitro studies, we developed a portable confocal Raman system with a handheld probe for clinical study. Using this portable system, we measured Raman spectra of 21 suspected nonmelanoma skin cancers in 19 patients with matched normal skin spectra. These spectra were input into nonlinear diagnostic algorithms to predict pathological designation. Results: All of the BCC (9/9), SCC (4/4), and inflamed scar tissues (8/8) were correctly predicted by the diagnostic algorithm, and 19 out of 21 normal tissues were correctly classified. This translates into a 100% (21/21) sensitivity and 91% (19/21) specificity for abnormality, with a 95% (40/42) overall classification accuracy. Conclusions: These findings reveal Raman microspectroscopy to be a viable tool for real‐time diagnosis and guidance of nonmelanoma skin cancer resection. Lesers Surg. Med. 40:461–467, 2008. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lsm.20653

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 218

Metadata

Authors
Lieber, C. A., Majumder, S. K., Ellis, D. L., Billheimer, D. D., & Mahadevan‐Jansen, A.
Venue
Lasers in Surgery and Medicine
Publisher
Wiley
Published
2008-08-25
Volume
40
Issue
7
Pages
461-467
ISSN
  • 0196-8092 (ISSN-L)
  • 1096-9101
OpenAlex
W1966524732
Cited by
218
References
3
FWCI
6.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo nonmelanoma skin cancer diagnosis using Raman microspectroscopy. https://app.cochat.ai/papers/10.1002/lsm.20653
The paper
Lieber, C. A., Majumder, S. K., Ellis, D. L., Billheimer, D. D., & Mahadevan‐Jansen, A. (2008). In vivo nonmelanoma skin cancer diagnosis using Raman microspectroscopy. Lasers in Surgery and Medicine. https://doi.org/10.1002/lsm.20653

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.