Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Different Methods of Creatinine Measurement Significantly Affect MELD Scores

Cholongitas, Evangelos, Marelli, Laura, Kerry, Andrew, Senzolo, Marco, Goodier, David W., Nair, Devaki, Thomas, Michael, Patch, David, Burroughs, Andrew K.·2007·Liver Transplantation

Abstract

Bilirubin (Bil) interferes with creatinine (Cr) measurement. Different laboratory methods are used to overcome this problem. Model for end-stage liver disease (MELD) scoring incorporates Cr and is used to prioritize patients for liver transplantation. Thus, MELD scores may vary with different Cr measurements influencing patients' priority. Our aim was to evaluate 4 different Cr assays (O'Leary modified Jaffe [mJCr], compensated [rate blanked] kinetic Jaffe [cJCr], enzymatic [ECr], and standard kinetic Jaffe [JCr]) in patients with abnormal liver function tests and assess changes in MELD score. A total of 403 consecutive samples from 158 patients' Cr assays were evaluated. Bland-Altman plots and MELD scores were also evaluated for each assay. Agreement was found to be poor among all Cr assays. Increased variability in Cr occurred with increasing Bil concentrations: Bil <100 μmol/L ≤3-point MELD variation - 3-point difference in 2%; Bil ≥400μmol/L ≤7-point MELD variation - ≥3-point difference in 78%. When MELD was ≥25 (mJCr as reference; mean, 30.5 points), MELD variation was greatest: mean, 28 (MELD cJCr), 27.5 (MELD ECr), and 28.4 (MELD JCr) (P < 0.001). In conclusion, there is poor agreement among different assays for Cr. As Bil concentration rises, there is greater variability in each creatinine measurements and thus greater variability in MELD scores that, this affect prioritization for liver transplantation. Liver Transpl, 2006. © 2006 AASLD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lt.20994

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 162

Metadata

Authors
Cholongitas, E., Marelli, L., Kerry, A., Senzolo, M., Goodier, D. W., Nair, D., Thomas, M., Patch, D., & Burroughs, A. K.
Venue
Liver Transplantation
Published
2007-04
Volume
13
Issue
4
Pages
523-529
ISSN
1527-6465 (ISSN-L)
OpenAlex
W2125103962
Cited by
162
References
2
FWCI
8.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Different Methods of Creatinine Measurement Significantly Affect MELD Scores. https://app.cochat.ai/papers/10.1002/lt.20994
The paper
Cholongitas, E., Marelli, L., Kerry, A., Senzolo, M., Goodier, D. W., Nair, D., Thomas, M., Patch, D., & Burroughs, A. K. (2007). Different Methods of Creatinine Measurement Significantly Affect MELD Scores. Liver Transplantation. https://doi.org/10.1002/lt.20994

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.