Influence of Satellite Groups on Telechelic Antimicrobial Functions of Polyoxazolines
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: The antimicrobial activity of poly(alkyloxazoline) telechelics with one quaternary N,N‐dimethyldodecylammonium (DDA) end group was found to be greatly controlled by the non‐bioactive distal end group, the so‐called satellite group. In systematic investigations, the nature of the latter groups was varied to explore the mechanism of the satellite effect. To this end, poly(2‐alkyl‐1,3‐oxazoline)s (alkyl = ethyl, methyl) with a DDA‐group at the terminating end and varying alkyl, aminoalkyl, and polyphenyloxazoline block satellite groups, have been synthesized. Poly(oxazoline) derivatives with polydispersity indices of 1.06–1.20 and molecular weights from 2 200 to 12 800 g · mol−1 could be obtained. The macromolecular structures have been confirmed by NMR spectroscopy and ESI‐MS measurements. The polymers were investigated with regard to their antibacterial efficiency towards the Gram‐positive bacterium Staphylococcus aureus and the Gram‐negative bacterium Escherichia coli. It was found that the introduction of alkyl chain satellites of 4–10 carbon atoms in length afforded antimicrobial activity of the polymers against both microbes that was about 2–3 times higher than that of the well‐known structurally comparable low molecular weight biocide, dodecyltrimethylammonium chloride (DTAC). Based on the antimicrobial effects of the investigated polymers, a mechanism for the satellite effect was proposed. magnified image
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agents that increase the permeability of the outer membrane
Vaara, M. (1992) · Microbiological Reviews · doi:10.1128/mr.56.3.395-411.1992 · Cited by 1,879
Permanent, nonleaching antibacterial surfaces: 1. Synthesis by atom transfer radical polymerization
Lee, S. B., Koepsel, R. R., Morley, S. W., Matyjaszewski, K., Sun, Y., & Russell, A. J. (2004) · Biomacromolecules · doi:10.1021/bm034352k · Cited by 545
Cited by
Polymeric materials with antimicrobial activity
Muñoz-Bonilla, A., & Fernández-García, M. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.08.005 · Cited by 1,221
Poly(2‐oxazoline)s: A Polymer Class with Numerous Potential Applications
Hoogenboom, R. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901607 · Cited by 889
Thermosensitive water-soluble copolymers with doubly responsive reversibly interacting entities
Dimitrov, I., Trzebicka, B., Müller, A. H. E., Dworak, A., & Tsvetanov, C. B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.07.001 · Cited by 750
Antimicrobial Polymers in Solution and on Surfaces: Overview and Functional Principles
Siedenbiedel, F., & Tiller, J. C. (2012) · Polymers · doi:10.3390/polym4010046 · Cited by 724
Self-citationAntimicrobial polymers: mechanism of action, factors of activity, and applications
Timofeeva, L., & Kleshcheva, N. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2920-9 · Cited by 579
Metadata
- Authors
- Waschinski, C. J., Herdes, V., Schueler, F., & Tiller, J. C.
- Venue
- Macromolecular Bioscience
- Publisher
- Wiley
- Published
- 2005-02-17
- Volume
- 5
- Issue
- 2
- Pages
- 149-156
- ISSN
- 1616-5187 (ISSN-L)
- 1616-5195
- OpenAlex
- W1982774179
- Cited by
- 123
- References
- 2
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.