CoChat

Green Process to Prepare Silk Fibroin/Gelatin Biomaterial Scaffolds

Lu, Qiang, Zhang, Xiaohui, Hu, Xiao, Kaplan, David L. · 2010 · Macromolecular Bioscience
Cited by 89

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A new all‐aqueous and green process is described to form three‐dimensional porous silk fibroin matrices with control of structural and morphological features. Silk‐based scaffolds are prepared using lyophilization. Gelatin is added to the aqueous silk fibroin solution to change the silk fibroin conformation and silk fibroin–water interactions through adjusting the hydrophilic interactions in silk fibroin–gelatin–water systems to restrain the formation of separate sheet like structures in the material, resulting in a more homogenous structure. Water annealing is used to generate insolubility in the silk fibroin–gelatin scaffold system, thereby avoiding the use of organic solvents such as methanol to lock in the β‐sheet structure. The adjusting of the concentration of gelatin, as well as the concentration of silk fibroin, leads to control of morphological and functional properties of the scaffolds. The scaffolds were homogeneous in terms of interconnected pores, with pore sizes ranging from 100 to 600 µm, depending on the concentration of silk fibroin used in the process. At the same time, the morphology of the scaffolds changed from lamellar sheets to porous structures based on the increase in gelatin content. Compared with salt‐leaching aqueous‐derived scaffolds and hexafluoroisopropanol (HFIP)‐derived scaffolds, these freeze‐dried scaffolds had a lower content of β‐sheet, resulting in more hydrophilic features. Most of gelatin was entrapped in the silk fibroin–gelatin scaffolds, without the burst release in PBS solution. During in vitro cell culture, these silk fibroin–gelatin scaffolds had improved cell‐compatibility than salt‐leaching silk fibroin scaffolds. This new process provides useful silk fibroin‐based scaffold systems for use in tissue engineering. Furthermore, the whole process is green, including all‐aqueous, room temperature and pressure, and without the use of toxic chemicals or solvents, offering new ways to load bioactive drugs or growth factors into the process. magnified image

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mabi.200900258

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 89

Metadata

Authors
Lu, Q., Zhang, X., Hu, X., & Kaplan, D. L.
Venue
Macromolecular Bioscience
Publisher
Wiley
Published
2010-03-04
Volume
10
Issue
3
Pages
289-298
ISSN
  • 1616-5187 (ISSN-L)
  • 1616-5195
OpenAlex
W2002050935
Cited by
89
References
3
FWCI
1.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.