The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Advances in Polymeric Systems for Tissue Engineering and Biomedical Applications
Abstract
The characteristics of tissue engineered scaffolds are major concerns in the quest to fabricate ideal scaffolds for tissue engineering applications. The polymer scaffolds employed for tissue engineering applications should possess multifunctional properties such as biocompatibility, biodegradability and favorable mechanical properties as it comes in direct contact with the body fluids in vivo. Additionally, the polymer system should also possess biomimetic architecture and should support stem cell adhesion, proliferation and differentiation. As the progress in polymer technology continues, polymeric biomaterials have taken characteristics more closely related to that desired for tissue engineering and clinical needs. Stimuli responsive polymers also termed as smart biomaterials respond to stimuli such as pH, temperature, enzyme, antigen, glucose and electrical stimuli that are inherently present in living systems. This review highlights the exciting advancements in these polymeric systems that relate to biological and tissue engineering applications. Additionally, several aspects of technology namely scaffold fabrication methods and surface modifications to confer biological functionality to the polymers have also been discussed. The ultimate objective is to emphasize on these underutilized adaptive behaviors of the polymers so that novel applications and new generations of smart polymeric materials can be realized for biomedical and tissue engineering applications.magnified image
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keun Kwon, I., Kidoaki, S., & Matsuda, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.007 · Cited by 607
Abidian, M. R., Corey, J. M., Kipke, D. R., & Martin, D. C. (2010) · Small · doi:10.1002/smll.200901868 · Cited by 405
Cited by
Overcoming the challenges in administering biopharmaceuticals: Formulation and delivery strategies
Mitragotri, S., Burke, P. A., & Langer, R. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4363 · Cited by 1,702
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Chitin and Chitosan: Structure, Properties and Applications in Biomedical Engineering
Islam, S., Bhuiyan, M. A. R., & Islam, M. N. (2017) · Journal of Polymers and the Environment · doi:10.1007/s10924-016-0865-5 · Cited by 738
Abrigo, M., McArthur, S. L., & Kingshott, P. (2014) · Macromolecular Bioscience · doi:10.1002/mabi.201300561 · Cited by 622
Biodegradable and electrically conducting polymers for biomedical applications
Guo, B., Glavas, L., & Albertsson, A.-C. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.06.003 · Cited by 592
Metadata
- Authors
- Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S.
- Venue
- Macromolecular Bioscience
- Publisher
- Wiley
- Published
- 2012-01-25
- Volume
- 12
- Issue
- 3
- Pages
- 286-311
- ISSN
- 1616-5187 (ISSN-L)
- 1616-5195
- OpenAlex
- W2076911232
- Cited by
- 201
- References
- 2
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in Polymeric Systems for Tissue Engineering and Biomedical Applications. https://app.cochat.ai/papers/10.1002/mabi.201100325
- The paper
- Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S. (2012). Advances in Polymeric Systems for Tissue Engineering and Biomedical Applications. Macromolecular Bioscience. https://doi.org/10.1002/mabi.201100325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.