Effect of sewage sludge addition on initial corrosion of 16Mo3 and 310S when exposed in a used wood fired boiler
Abstract
With an expanding use of low quality bio fuels, corrosion problems on water wall tubes are increasing. In this study, the possible corrosion reducing effect when adding digested sewage sludge to the fuel in a used wood (also known as waste or recycled wood) fired furnace has been evaluated. The low alloyed steel 16Mo3 and the stainless steel 310S were exposed for 14.25 h at the furnace wall position when firing only used wood and used wood with sewage sludge additions. The exposures were performed in a bubbling fluidized bed boiler and the metal temperature of the test samples was controlled to 350 °C. Chemical analysis of the deposits and microscopic evaluation of the metallic samples showed reduced amount of alkali metals and chlorine in the deposit together with reduced initial corrosion for both materials when co‐firing with digested sewage sludge. In the corrosion process, metal chlorides were formed for both materials when firing only used wood, iron chlorides for the low alloyed steel, and chromium chlorides for the stainless steel. When co‐firing with sewage sludge, this behavior was suppressed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Additives create higher melting point slags that reduce the tendency of slag deposition.
“The additives create higher melting point slags that reduce the tendency of slag deposition [25, 26].”
From High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review (2024) · cites this paper as [26]
Cites
Grabke, H. J., Reese, E., & Spiegel, M. (1995) · Corrosion Science · doi:10.1016/0010-938x(95)00011-8 · Cited by 537 · see citing works
Alkali Induced High Temperature Corrosion of Stainless Steel: The Influence of NaCl, KCl and CaCl2
Karlsson, S., Pettersson, J., Johansson, L. G., & Svensson, J. E. (2012) · Oxidation of Metals · doi:10.1007/s11085-012-9293-7 · Cited by 118 · see citing works
Initial Stages of the HCl-Induced High-Temperature Corrosion of Alloy 310
Folkeson, N., Johansson, L.-G., & Svensson, J.-E. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2754174 · Cited by 66 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review
Khantisopon, K., Singh, S., Jitputti, J., Berndt, C. C., & Ang, A. S. M. (2024) · High Temperature Corrosion of Materials · doi:10.1007/s11085-024-10251-0 · Cited by 24 · see citing works
- Authors
- Talus, A., Alipour, Y., Norling, R., & Henderson, P.
- Affiliations
- Swerea KIMAB Isafjordsgatan 28A SE‐164 40 Kista Sweden
- KTH Royal Institute of Technology (SE)
- Vattenfall (Sweden) (SE)
- Corresponding author
- Talus, A.
- Venue
- Materials and Corrosion
- Publisher
- Wiley
- Published
- 2016-03-29
- Volume
- 67
- Issue
- 7
- Pages
- 683-692
- ISSN
- 0043-2822 (ISSN-L)
- 0947-5117
- 1521-4176
- OpenAlex
- W2330101381
- Cited by
- 7
- References
- 3
- Citations by year
- 2024: 1 · 2023: 1 · 2022: 2 · 2020: 1 · 2019: 1 · 2017: 1
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Materials and Corrosion (publishedVersion)
- Funders
- Swedish Energy Agency (39270‐1)
- Vattenfall
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › High-Temperature Coating Behaviors
- Physical Sciences › Engineering › Biomedical Engineering › Thermochemical Biomass Conversion Processes
- Physical Sciences › Materials Science › Materials Chemistry › Corrosion Behavior and Inhibition
- Keywords
- wood-fired boilers, corrosion initiation, 310S stainless steel, waterwall tubes, metal chlorides, chlorine, iron chloride, chromium chloride, bubbling fluidized bed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review