The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Abstract
Selected ion flow tube mass spectrometry (SIFT‐MS) is a new analytical technique for the real‐time quantification of several trace gases simultaneously in air and breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas using H 3 O+, NO+, and O precursor ions. Reactions between the precursor ions and trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream mass spectrometer, thus effecting quantification. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT‐MS down to ppb levels, obviating sample collection and calibration. Illustrative examples of SIFT‐MS studies include (i) analysis of gases from combustion engines, animals and their waste, and food; (ii) breath and urinary headspace studies of metabolites, ethanol metabolism, elevated acetone during ovulation, and exogenous compounds; and (iii) urinary infection and the presence of tumors, the influence of dialysis on breath ammonia, acetone, and isoprene, and acetaldehyde released by cancer cells in vitro. Flowing afterglow mass spectrometry (FA‐MS) is briefly described, which allows on‐line quantification of deuterium in breath water vapor. © 2004 Wiley Periodicals, Inc., Mass Spec Rev 24:661–700, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Evaluated Gas Phase Basicities and Proton Affinities of Molecules: An Update
Hunter, E. P. L., & Lias, S. G. (1998) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.556018 · Cited by 2,702
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Increased nitric oxide in exhaled air of asthmatic patients
Kharitonov, S. A., Yates, D., Robbins, R. A., Barnes, P. J., Logan-Sinclair, R., & Shinebourne, E. A. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90931-8 · Cited by 1,436
Parametrization of the ion–polar molecule collision rate constant by trajectory calculations
Su, T., & Chesnavich, W. J. (1982) · The Journal of Chemical Physics · doi:10.1063/1.442828 · Cited by 1,403
Transport properties of gaseous ions over a wide energy range
Ellis, H. W., Pai, R. Y., McDaniel, E. W., Mason, E. A., & Viehland, L. A. (1976) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(76)90001-2 · Cited by 967
The mobility and diffusion of ions in gases
McDaniel, E. W., & Mason, E. A. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 942
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Gas-Phase Ion and Neutral Thermochemistry
Dobbins, R. A., Mohammed, K., & Sullivan, D. A. (1988) · Cited by 690
Handbook of Stable Isotope Analytical Techniques
Groot, D. H. L. F. (2004) · Elsevier eBooks · Cited by 516
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Self-citationThe diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399
The selected ion flow tube (SIFT); A technique for studying ion-neutral reactions
Adams, N. G., & Smith, D. (1976) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(76)80133-7 · Cited by 397
Self-citationTransport Properties of Gaseous Ions over a Wide Energy Range, IV
Viehland, L. A., & Mason, E. A. (1995) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1995.1004 · Cited by 336
Diskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
Self-citationBouchoux, G., Salpin, J., & Leblanc, D. (1996) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04353-5 · Cited by 232
SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of alcohols
Spanel, P., & Smith, D. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00085-2 · Cited by 231
Self-citationSelected ion flow tube: a technique for quantitative trace gas analysis of air and breath
Španěl, P., & Smith, D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523843 · Cited by 229
Self-citationSIFT studies of the reactions of H3O+, NO+ and O2+ with a series of aldehydes and ketones
Španěl, P., Ji, Y., & Smith, D. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00166-3 · Cited by 226
Self-citationElectrospray: Its potential and limitations as an ionization method for biomolecules
Mann, M. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210251104 · Cited by 225
An index of the literature for bimolecular gas phase cation-molecule reaction kinetics
Anicich, V. G. (2003) · NASA Technical Reports Server (NASA) · Cited by 207
Španěl, P., Smith, D., Holland, T. A., Singary, W. A., & Elder, J. B. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990730)13:14<1354::aid-rcm641>3.0.co;2-j · Cited by 189
Self-citationSmith, D., Spanel, P., & Davies, S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1584 · Cited by 180
Self-citationThe Novel Selected-ion Flow Tube Approach to Trace Gas Analysis of Air and Breath
Smith, D. C., & Španěl, P. (1996) · Rapid Communications in Mass Spectrometry · Cited by 177
Self-citationIsoprene — The main hydrocarbon in human breath
Gelmont, D., Stein, R. A., & Mead, J. F. (1981) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(81)90782-8 · Cited by 175
Smith, D., Wang, T., Sulé‐Suso, J., Španěl, P., & Haj, A. E. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.984 · Cited by 158
Self-citationŠpaněl, P., & Smith, D. C. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00246-2 · Cited by 142
Self-citationSmith, D. C., & Španěl, P. (1996) · International Reviews in Physical Chemistry · doi:10.1080/01442359609353183 · Cited by 135
Self-citationAdvances in Ion Mobility Spectrometry: 1980–1990
Eiceman, G. A. (1991) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408349108055024 · Cited by 135
Španěl, P., & Smith, D. C. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100042a033 · Cited by 115
Self-citationUrinary nitrite: more than a marker of infection
Lundberg, J. O. N., Carlsson, S., Engstrand, L., Morcos, E., Wiklund, N. P., & Weitzberg, E. (1997) · Urology · doi:10.1016/s0090-4295(97)00257-4 · Cited by 108
Hyšpler, R., Crhová, Š., Gasparič, J., Zadák, Z., Čı́žková, M., & Balasová, V. (2000) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00423-5 · Cited by 105
Španěl, P., & Smith, D. C. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.265 · Cited by 104
Self-citationIon-Trap Detection of Volatile Organic Compounds in Alveolar Breath
Phillips, M., & Greenberg, J. H. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.1.60 · Cited by 99
Španěl, P., Davies, S., & Smith, D. C. (1998) · Rapid Communications in Mass Spectrometry · Cited by 85
Self-citationSmith, D. C., Wang, T., & Španěl, P. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/301 · Cited by 81
Self-citationA new ‘online’ method to measure increased exhaled isoprene in end‐stage renal failure
Davies, S., Španěl, P., & Smith, D. C. (2001) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/16.4.836 · Cited by 80
Self-citationŠpaněl, P., & Smith, D. C. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14031-9 · Cited by 77
Self-citationAn ion/molecule-reaction mass spectrometer used for on-line trace gas analysis
Lindinger, W., Hirber, J., & Paretzke, H. G. (1993) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)87031-m · Cited by 76
Španěl, P., Pavlík, M., & Smith, D. C. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04164-g · Cited by 74
Self-citationSmith, D. C., Diskin, A. M., Ji, Y., & Španěl, P. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00478-x · Cited by 71
Self-citationŠpaněl, P., & Smith, D. C. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00253-7 · Cited by 69
Self-citationSelected ion flow tube mass spectrometry of urine headspace
Smith, D. C., Španěl, P., Holland, T. A., Singari, W. A., & Elder, J. B. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990430)13:8 · Cited by 67
Self-citationApplications of proton transfer reactions to gas analysis
Lagg, A., Taucher, J. A., Hansel, A., & Lindinger, W. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)03965-8 · Cited by 66
Diskin, A. M., Wang, T., Smith, D. C., & Španěl, P. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00662-0 · Cited by 63
Self-citationClough, T. J., Sherlock, R. R., Mautner, M. N., Milligan, D. B., Wilson, P. F., Freeman, C. G., & McEwan, M. J. (2003) · Soil Research · doi:10.1071/sr02105 · Cited by 61
Quantification of hydrogen cyanide in humid air by selected ion flow tube mass spectrometry
Španěl, P., Wang, T., & Smith, D. C. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1566 · Cited by 61
Self-citationŠpaněl, P., & Smith, D. C. (1999) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(99)00103-7 · Cited by 58
Self-citationSmith, D. C., Španěl, P., & Jones, J. B. (2000) · Bioresource Technology · doi:10.1016/s0960-8524(00)00034-1 · Cited by 49
Self-citationDiskin, A. M., Španěl, P., & Smith, D. C. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/314 · Cited by 47
Self-citationTHE SELECTED ION FLOW TUBE (SIFT)—A NOVEL TECHNIQUE FOR BIOLOGICAL MONITORING
Španěl, P., Rolfe, P. J., Rajan, B., & Smith, D. C. (1996) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/40.6.615 · Cited by 47
Self-citationŠpaněl, P., Diskin, A. M., Abbott, S. M., Wang, T., & Smith, D. C. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.849 · Cited by 45
Self-citationSmith, D. C., Španěl, P., Thompson, J. M., Rajan, B., Cocker, J., & Rolfe, P. J. (1998) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1998.10389161 · Cited by 44
Self-citationSmith, D. C., Cheng, P., & Španěl, P. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.691 · Cited by 44
Self-citationŠpaněl, P., Wang, T., & Smith, D. C. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00724-8 · Cited by 43
Self-citationAssessment of Rumen Processes by Selected-Ion-Flow-Tube Mass Spectrometric Analysis of Rumen Gases
Dewhurst, R. J., Evans, R. T., Mottram, T. T. F., Španěl, P., & Smith, D. C. (2001) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(01)70176-2 · Cited by 42
Self-citationAlcohol in breath and blood: a selected ion flow tube mass spectrometric study
Wilson, P. F., Freeman, C. G., McEwan, M. J., Milligan, D. B., Allardyce, R. A., & Shaw, G. M. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.244 · Cited by 41
Quantification of passive smoking using proton-transfer-reaction mass spectrometry
Prazeller, P., Karl, T., Jordan, A., Holzinger, R., Hansel, A., & Lindinger, W. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14153-2 · Cited by 40
Smith, D. C., Engel, B., Diskin, A. M., Španěl, P., & Davies, S. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.6.1295 · Cited by 35
Self-citationŠpaněl, P., & Smith, D. C. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00157-4 · Cited by 31
Self-citationl, P. P., & Smith, D. C. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(20000430)14:8<646::aid-rcm926>3.0.co;2-7 · Cited by 31
Self-citationŠpaněl, P., & Smith, D. C. (1999) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14099-x · Cited by 30
Self-citationSmith, D. C., Wang, T., & Španěl, P. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.550 · Cited by 29
Self-citationA SIFT study of the reactions of H2ONO+ ions with several types of organic molecules
Smith, D. C., Wang, T., & Španěl, P. (2003) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(03)00341-5 · Cited by 29
Self-citationAcetonitrile as a possible marker of current cigarette smoking
Houeto, P., Hoffman, J. R., Got, P., Vu, B. D., & Band, F. (1997) · Human & Experimental Toxicology · doi:10.1177/096032719701601105 · Cited by 28
Villinger, J., Federer, W., Resch, R., et al. (1993) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/932017 · Cited by 27
The selected ion flow tube (SIFT)?A novel technique for biological monitoring
PANL, P. (1996) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(96)00028-2 · Cited by 25
Self-citationWang, T., Smith, D. C., & Španěl, P. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.804 · Cited by 21
Self-citationReal-Time, High-Resolution Quantitative Measurement of Multiple Soil Gas Emissions
Milligan, D. B., Wilson, P. F., Mautner, M. N., Freeman, C. G., McEwan, M. J., Clough, T. J., & Sherlock, R. R. (2002) · Journal of Environmental Quality · doi:10.2134/jeq2002.0515 · Cited by 18
Cited by
de Gouw, J., & Warneke, C. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20119 · Cited by 1,055
Advanced methods of plant disease detection. A review
Martinelli, F., Scalenghe, R., Davino, S., Panno, S., Scuderi, G., Ruisi, P., Villa, P., Stroppiana, D., Boschetti, M., Goulart, L. R., et al. (2015) · Agronomy for Sustainable Development · doi:10.1007/s13593-014-0246-1 · Cited by 964
Proton-Transfer Reaction Mass Spectrometry
Blake, R. S., Monks, P. S., & Ellis, A. M. (2009) · Chemical Reviews · doi:10.1021/cr800364q · Cited by 745
A European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Righettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Metadata
- Authors
- Smith, D., & Španěl, P.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2004-10-19
- Volume
- 24
- Issue
- 5
- Pages
- 661-700
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2092538532
- Cited by
- 801
- References
- 70
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.