The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Automated protein identification by tandem mass spectrometry: Issues and strategies
Abstract
Protein identification by tandem mass spectrometry (MS/MS) is key to most proteomics projects and has been widely explored in bioinformatics research. Obtaining good and trustful identification results has important implications for biological and clinical work. Although well matured, automated software identification of proteins from MS/MS data still faces a number of obstacles due to the complexity of the proteome or procedural issues of mass spectrometry data acquisition. Expected or unexpected modifications of the peptide sequences, polymorphisms, errors in databases, missed or non‐specific cleavages, unusual fragmentation patterns, and single MS/MS spectra of multiple peptides of the same m/z are so many pitfalls for identification algorithms. A lot of research work has been carried out in recent years that yielded new strategies to handle a number of these issues. Multiple MS/MS identification algorithms are now available or have been theoretically described. The difficulty resides in choosing the most adapted method for each type of spectra being identified. This review presents an overview of the state‐of‐the‐art bioinformatics approaches to the identification of proteins by MS/MS to help the reader doing the spadework of finding the right tools among the many possibilities offered. © 2005 Wiley Periodicals, Inc. Mass Spec Rev 25:235–254, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Inoue, N., Dong, R., Hirata, R. K., & Russell, D. W. (2001) · Molecular Therapy · doi:10.1006/mthe.2001.0283 · Cited by 62
Cited by
Advances and Trends in Omics Technology Development
Dai, X., & Shen, L. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.911861 · Cited by 535
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
Kim, B. S., Das, S., Jang, J., & Cho, D.-W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00808 · Cited by 465
Mass spectrometry for structural characterization of therapeutic antibodies
Zhang, Z., Pan, H., & Chen, X. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20190 · Cited by 316
Spivak, M., Weston, J., Bottou, L., Käll, L., & Noble, W. S. (2009) · Journal of Proteome Research · doi:10.1021/pr801109k · Cited by 282
Biomarker detection technologies and future directions
Nimse, S. B., Sonawane, M. D., Song, K.-S., & Kim, T. (2016) · The Analyst · doi:10.1039/c5an01790d · Cited by 275
Mass Spectrometry Based Glycoproteomics—From a Proteomics Perspective
Pan, S., Chen, R., Aebersold, R., & Brentnall, T. A. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r110.003251 · Cited by 267
Regulation of decellularized matrix mediated immune response
Chakraborty, J., Roy, S., & Ghosh, S. (2020) · Biomaterials Science · doi:10.1039/c9bm01780a · Cited by 130
Metadata
- Authors
- Hernandez, P., Müller, M., & Appel, R. D.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2005-11-11
- Volume
- 25
- Issue
- 2
- Pages
- 235-254
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2015840688
- Cited by
- 164
- References
- 4
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.