The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Residue analysis of 500 high priority pesticides: Better by GC–MS or LC–MS/MS?
Open accessAbstract
This overview evaluates the capabilities of mass spectrometry (MS) in combination with gas chromatography (GC) and liquid chromatography (LC) for the determination of a multitude of pesticides. The selection of pesticides for this assessment is based on the status of production, the existence of regulations on maximum residue levels in food, and the frequency of residue detection. GC–MS with electron impact (EI) ionization and the combination of LC with tandem mass spectrometers (LC–MS/MS) using electrospray ionization (ESI) are identified as techniques most often applied in multi‐residue methods for pesticides at present. Therefore, applicability and sensitivity obtained with GC–EI–MS and LC–ESI–MS/MS is individually compared for each of the selected pesticides. Only for one substance class only, the organochlorine pesticides, GC‐MS achieves better performance. For all other classes of pesticides, the assessment shows a wider scope and better sensitivity if detection is based on LC–MS. © 2006 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Pesticide manual: a world compendium
(1992) · Choice Reviews Online · doi:10.5860/choice.29-4534 · Cited by 1,117
Lehotay, S. J., Kok, A. D., Hiemstra, M., & Bodegraven, P. V. (2005) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/88.2.595 · Cited by 662
Thiamethoxam is a neonicotinoid precursor converted to clothianidin in insects and plants
Nauen, R., Ebbinghaus-Kintscher, U., Salgado, V. L., & Kaussmann, M. (2003) · Pesticide Biochemistry and Physiology · doi:10.1016/s0048-3575(03)00065-8 · Cited by 490
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Evaluation of analyte protectants to improve gas chromatographic analysis of pesticides
Anastassiades, M., Maštovská, K., & Lehotay, S. J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01208-1 · Cited by 368
Picó, Y., Blasco, C., & Font, G. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10071 · Cited by 299
Štajnbaher, D., & Zupančič-Kralj, L. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)01211-1 · Cited by 277
Sannino, A., Bolzoni, L., & Bandini, M. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.02.078 · Cited by 254
Fillion, J., Sauvé, F., & Selwyn, J. (2000) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/83.3.698 · Cited by 251
Thurman, E. M., Ferrer, I., & Barceló, D. (2001) · Analytical Chemistry · doi:10.1021/ac010506f · Cited by 220
Cited by
Mullin, C. A., Frazier, M., Frazier, J. L., Ashcraft, S., Simonds, R., vanEngelsdorp, D., & Pettis, J. S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009754 · Cited by 1,498
An extensive review on the consequences of chemical pesticides on human health and environment
Rani, L., Thapa, K., Kanojia, N., Sharma, N., Singh, S., Grewal, A. S., Srivastav, A. L., & Kaushal, J. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.124657 · Cited by 1,427
Pesticides and honey bee toxicity – USA
Johnson, R. M., Ellis, M. D., Mullin, C. A., & Frazier, M. (2010) · Apidologie · doi:10.1051/apido/2010018 · Cited by 672
Payá, P., Anastassiades, M., Mack, D., Sigalova, I., Tasdelen, B., Oliva, J., & Barba, A. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1610-7 · Cited by 642
Nanomaterials for Sensing and Destroying Pesticides
Aragay, G., Pino, F., & Merkoçi, A. (2012) · Chemical Reviews · doi:10.1021/cr300020c · Cited by 573
Persistent Organic Pollutants in Food: Contamination Sources, Health Effects and Detection Methods
Guo, W., Pan, B., Sakkiah, S., Yavas, G., Ge, W., Zou, W., Tong, W., & Hong, H. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16224361 · Cited by 435
Properties and determination of pesticides in fruits and vegetables
Fenik, J., Tankiewicz, M., & Biziuk, M. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.02.008 · Cited by 391
Prasse, C., Stalter, D., Schulte-Oehlmann, U., Oehlmann, J., & Ternes, T. A. (2015) · Water Research · doi:10.1016/j.watres.2015.09.023 · Cited by 319
Nanotechnology-based recent approaches for sensing and remediation of pesticides
Rawtani, D., Khatri, N., Tyagi, S., & Pandey, G. (2018) · Journal of Environmental Management · doi:10.1016/j.jenvman.2017.11.037 · Cited by 303
Bruzzoniti, M. C., Checchini, L., De Carlo, R. M., Orlandini, S., Rivoira, L., & Del Bubba, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7798-4 · Cited by 301
Economou, A., Botitsi, H., Antoniou, S., & Tsipi, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.06.031 · Cited by 283
Environmental Mass Spectrometry: Emerging Contaminants and Current Issues
Richardson, S. D. (2008) · Analytical Chemistry · doi:10.1021/ac800660d · Cited by 268
Rodil, R., Quintana, J. B., López-Mahía, P., Muniategui-Lorenzo, S., & Prada-Rodríguez, D. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.041 · Cited by 267
Sample treatment and determination of pesticide residues in fatty vegetable matrices: A review
Gilbert-López, B., García-Reyes, J. F., & Molina-Díaz, A. (2009) · Talanta · doi:10.1016/j.talanta.2009.04.022 · Cited by 265
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D. (2007) · Analytical Chemistry · doi:10.1021/ac070719q · Cited by 233
González‐Mariño, I., Quintana, J. B., Rodríguez, I., & Cela, R. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4069 · Cited by 160
Review of the molluscicide metaldehyde in the environment
Castle, G. D., Mills, G. A., Gravell, A., Jones, L., Townsend, I., Cameron, D. G., & Fones, G. R. (2017) · Environmental Science: Water Research & Technology · doi:10.1039/c7ew00039a · Cited by 98
Quintana, J., de la Cal, A., & Boleda, M. R. (2019) · Science of The Total Environment · doi:10.1016/j.scitotenv.2019.07.317 · Cited by 62
Mansilha, C., Carvalho, A., Guimarães, P., & Espinha Marques, J. (2014) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/15287394.2014.909301 · Cited by 50
Metadata
- Authors
- Alder, L., Greulich, K., Kempe, G., & Vieth, B.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2006-06-05
- Volume
- 25
- Issue
- 6
- Pages
- 838-865
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2008914876
- Cited by
- 623
- References
- 46
- FWCI
- 45.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.