Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 293

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Cluster secondary ion mass spectrometry of polymers and related materials

Mahoney, Christine M.·2010·Mass Spectrometry Reviews

Abstract

Cluster secondary ion mass spectrometry (cluster SIMS) has played a critical role in the characterization of polymeric materials over the last decade, allowing for the ability to obtain spatially resolved surface and in‐depth molecular information from many polymer systems. With the advent of new molecular sources such as ${\rm C}_{60}^ +$, ${\rm Au}_3^ +$, ${\rm SF}_5^ +$, and ${\rm Bi}_3^ +$, there are considerable increases in secondary ion signal as compared to more conventional atomic beams (Ar+, Cs+, or Ga+). In addition, compositional depth profiling in organic and polymeric systems is now feasible, without the rapid signal decay that is typically observed under atomic bombardment. The premise behind the success of cluster SIMS is that compared to atomic beams, polyatomic beams tend to cause surface‐localized damage with rapid sputter removal rates, resulting in a system at equilibrium, where the damage created is rapidly removed before it can accumulate. Though this may be partly true, there are actually much more complex chemistries occurring under polyatomic bombardment of organic and polymeric materials, which need to be considered and discussed to better understand and define the important parameters for successful depth profiling. The following presents a review of the current literature on polymer analysis using cluster beams. This review will focus on the surface and in‐depth characterization of polymer samples with cluster sources, but will also discuss the characterization of other relevant organic materials, and basic polymer radiation chemistry. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:247–293, 2010

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mas.20233

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Metadata

Authors
Mahoney, C. M.
Venue
Mass Spectrometry Reviews
Publisher
Wiley
Published
2009-05-15
Volume
29
Issue
2
Pages
247-293
ISSN
  • 0277-7037 (ISSN-L)
  • 1098-2787
OpenAlex
W2162506410
Cited by
293
References
40
FWCI
22.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cluster secondary ion mass spectrometry of polymers and related materials. https://app.cochat.ai/papers/10.1002/mas.20233
The paper
Mahoney, C. M. (2010). Cluster secondary ion mass spectrometry of polymers and related materials. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.20233

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.