Atmospheric pressure ion sources
Abstract
This review of atmospheric pressure ion sources discusses major developments that have occurred since 1991. Advances in the instrumentation and understanding of the key physical principles are the primary focus. Developments with electrospray and atmospheric pressure chemical ionization and variations encompassing adaptations for surface analysis, ambient air analysis, high throughput, and modification of the ionization mechanism are covered. An important and limiting consequence of atmospheric pressure chemical ionization, chemical noise, is discussed as is techniques being employed to ameliorate the problem. Ion transfer and transport from atmospheric pressure into deep vacuum is an area undergoing constant improvement and refinement so is given considerable consideration in this review. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 28:870–897, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Femtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry
Wilm, M., Shevchenko, A., Houthaeve, T., Breit, S., Schweigerer, L., Fotsis, T., & Mann, M. (1996) · Nature · doi:10.1038/379466a0 · Cited by 1,680
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Cited by
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Ambient Ionization Mass Spectrometry
Huang, M.-Z., Yuan, C.-H., Cheng, S.-C., Cho, Y.-T., & Shiea, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073702 · Cited by 306
Kammeijer, G. S. M., Kohler, I., Jansen, B. C., Hensbergen, P. J., Mayboroda, O. A., Falck, D., & Wuhrer, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00479 · Cited by 74
Metadata
- Authors
- Covey, T. R., Thomson, B. A., & Schneider, B. B.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2009-07-22
- Volume
- 28
- Issue
- 6
- Pages
- 870-897
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W4211180812
- Cited by
- 264
- References
- 95
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.