The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Metabolomic applications of HILIC–LC–MS
Abstract
Hydrophilic interaction liquid chromatography (HILIC), although not a new technique, has enjoyed a recent renaissance with the introduction of robust and reproducible stationary phases. It is consequently finding application in metabolomics studies, which have traditionally relied on the stability of reversed phases (RPs), since the biofluids analyzed are predominantly aqueous and thus contain many polar analytes. HILIC's retention of those polar compounds and use of solvents readily compatible with mass spectrometry have seen its increasing adoption in studies of complex aqueous metabolomes. This review describes the stationary phases and their features, surveys HILIC–LC–MS's role in metabolomics experiments, discusses approaches to data extraction and analysis including multivariate analysis, and reviews the literature on HILIC–MS applications in metabolomics. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:671–684, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A leisurely look at the bootstrap, the jackknife, and cross-validation
Efron, B., & Gong, G. (1983) · The American Statistician · doi:10.1080/00031305.1983.10483087 · Cited by 3,229
Microbial metabolomics: toward a platform with full metabolome coverage
Werf, M. J. V. D., Overkamp, K. M., Muilwijk, B., Coulier, L., & Hankemeier, T. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.07.022 · Cited by 207
Cited by
Creek, D. J., Jankevics, A., Breitling, R., Watson, D. G., Barrett, M. P., & Burgess, K. E. V. (2011) · Analytical Chemistry · doi:10.1021/ac2021823 · Cited by 344
Integration of GC–MS and LC–MS for untargeted metabolomics profiling
Zeki, Ö. C., Eylem, C. C., Reçber, T., Kır, S., & Nemutlu, E. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113509 · Cited by 336
Advances in metabolite identification
Wishart, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.155 · Cited by 284
Statistical workflow for feature selection in human metabolomics data
Antonelli, J., Claggett, B. L., Henglin, M., Kim, A., Ovsak, G., Kim, N., Deng, K., Rao, K., Tyagi, O., Watrous, J. D., et al. (2019) · Metabolites · doi:10.3390/metabo9070143 · Cited by 88
Guo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80
Metadata
- Authors
- Cubbon, S., Antonio, C., Wilson, J., & Thomas‐Oates, J.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2009-06-25
- Volume
- 29
- Issue
- 5
- Pages
- 671-684
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2101989062
- Cited by
- 184
- References
- 2
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metabolomic applications of HILIC–LC–MS. https://app.cochat.ai/papers/10.1002/mas.20252
- The paper
- Cubbon, S., Antonio, C., Wilson, J., & Thomas‐Oates, J. (2010). Metabolomic applications of HILIC–LC–MS. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.20252
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.