The DOI matches its Crossref record; 111 of the 111 references it cites were found in a registry or an index.
Progress in SIFT‐MS: Breath analysis and other applications
Abstract
The development of selected ion flow tube mass spectrometry, SIFT‐MS, is described from its inception as the modified very large SIFT instruments used to demonstrate the feasibility of SIFT‐MS as an analytical technique, towards the smaller but bulky transportable instruments and finally to the current smallest Profile 3 instruments that have been located in various places, including hospitals and schools to obtain on‐line breath analyses. The essential physics and engineering principles are discussed, which must be appreciated to design and construct a SIFT‐MS instrument. The versatility and sensitivity of the Profile 3 instrument is illustrated by typical mass spectra obtained using the three precursor ions H 3 O+, NO+ and ${\rm O}_{{\rm 2}}^{{\rm + } \cdot }$, and the need to account for differential ionic diffusion and mass discrimination in the analytical algorithms is emphasized to obtain accurate trace gas analyses. The performance of the Profile 3 instrument is illustrated by the results of several pilot studies, including (i) on‐line real time quantification of several breath metabolites for cohorts of healthy adults and children, which have provided representative concentration/population distributions, and the comparative analyses of breath exhaled via the mouth and nose that identify systemic and orally‐generated compounds, (ii) the enhancement of breath metabolites by drug ingestion, (iii) the identification of HCN as a marker of Pseudomonas colonization of the airways and (iv) emission of volatile compounds from urine, especially ketone bodies, and from skin. Some very recent developments are discussed, including the quantification of carbon dioxide in breath and the combination of SIFT‐MS with GC and ATD, and their significance. Finally, prospects for future SIFT‐MS developments are alluded to. © 2010 Wiley Periodicals, Inc., Mass Spec Rev 30:236–267, 2011
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Self-citationProton-Transfer Reaction Mass Spectrometry
Blake, R. S., Monks, P. S., & Ellis, A. M. (2009) · Chemical Reviews · doi:10.1021/cr800364q · Cited by 745
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Detection of Lung Cancer With Volatile Markers in the Breatha
Phillips, M., Cataneo, R. N., Cummin, A. R. C., Gagliardi, A. J., Gleeson, K., Greenberg, J., Maxfield, R. A., & Rom, W. N. (2003) · Chest · doi:10.1378/chest.123.6.2115 · Cited by 567
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Self-citationThe diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399
The selected ion flow tube (SIFT); A technique for studying ion-neutral reactions
Adams, N. G., & Smith, D. (1976) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(76)80133-7 · Cited by 397
Self-citationTurner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Self-citationThe potential of the hydrocarbon breath test as a measure of lipid peroxidation
Frank Kneepkens, C. M., Lepage, G., & Roy, C. C. (1994) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(94)90110-4 · Cited by 369
Solid-Phase Microextraction for the Analysis of Human Breath
Grote, C., & Pawliszyn, J. (1997) · Analytical Chemistry · doi:10.1021/ac960749l · Cited by 300
Ligor, M., Ligor, T., Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Denz, H., Fiegl, M., Hilbe, W., Weiss, W., et al. (2009) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2009.133 · Cited by 262
Jordan, A., Haidacher, S., Hanel, G., Hartungen, E., Herbig, J., Märk, L., Schottkowsky, R., Seehauser, H., Sulzer, P., & Märk, T. D. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.06.006 · Cited by 249
Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring
(2005) · doi:10.1142/5796 · Cited by 247
Diskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
Self-citationSIFT studies of the reactions of H3O+, NO+ and O2+ with a series of alcohols
Spanel, P., & Smith, D. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00085-2 · Cited by 231
Self-citationSelected ion flow tube: a technique for quantitative trace gas analysis of air and breath
Španěl, P., & Smith, D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523843 · Cited by 229
Self-citationSIFT studies of the reactions of H3O+, NO+ and O2+ with a series of aldehydes and ketones
Španěl, P., Ji, Y., & Smith, D. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00166-3 · Cited by 226
Self-citationExhaled leukotrienes and prostaglandins in asthma
Montuschi, P., & Barnes, P. J. (2002) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2002.122461 · Cited by 220
Breath acetone is a reliable indicator of ketosis in adults consuming ketogenic meals,,
Musa-Veloso, K., Likhodii, S. S., & Cunnane, S. C. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.1.65 · Cited by 218
Cadaverine as a Putative Component of Oral Malodor
Goldberg, S., Kozlovsky, A., Gordon, D., Gelernter, I., Sintov, A. C., & Rosenberg, M. (1994) · Journal of Dental Research · doi:10.1177/00220345940730060701 · Cited by 205
Breath Analysis: The Approach Towards Clinical Applications
Amann, A., Spanel, P., & Smith, D. (2007) · Mini-Reviews in Medicinal Chemistry · doi:10.2174/138955707779802606 · Cited by 198
Self-citationCurrent Status of Methods and Techniques for Breath Analysis
Cao, W., & Duan, Y. (2007) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340600976499 · Cited by 191
Španěl, P., Smith, D., Holland, T. A., Singary, W. A., & Elder, J. B. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990730)13:14<1354::aid-rcm641>3.0.co;2-j · Cited by 189
Self-citationSmith, D., Spanel, P., & Davies, S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1584 · Cited by 180
Self-citationThe Novel Selected-ion Flow Tube Approach to Trace Gas Analysis of Air and Breath
Smith, D. C., & Španěl, P. (1996) · Rapid Communications in Mass Spectrometry · Cited by 177
Self-citationIsoprene — The main hydrocarbon in human breath
Gelmont, D., Stein, R. A., & Mead, J. F. (1981) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(81)90782-8 · Cited by 175
Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037013 · Cited by 164
Self-citationSmith, D., Wang, T., Sulé‐Suso, J., Španěl, P., & Haj, A. E. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.984 · Cited by 158
Self-citationKato, S., Burke, P., Koch, T. H., & Bierbaum, V. M. (2001) · Analytical Chemistry · doi:10.1021/ac001498q · Cited by 157
Turner, C., Španěl, P., & Smith, D. C. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/007 · Cited by 150
Self-citationEnderby, B., Smith, D. C., Carroll, W. D., & Lenney, W. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.20963 · Cited by 148
Self-citationCarroll, W. D., Lenney, W., Wang, T., Španěl, P., Alcock, A., & Smith, D. C. (2005) · Pediatric Pulmonology · doi:10.1002/ppul.20170 · Cited by 148
Self-citationThe challenge of breath analysis for clinical diagnosis and therapeutic monitoring
Smith, D. C., & Španěl, P. (2007) · The Analyst · doi:10.1039/b700542n · Cited by 145
Self-citationŠpaněl, P., & Smith, D. C. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00246-2 · Cited by 142
Self-citationKushch, I., Schwarz, K., Schwentner, L., Baumann, B., Dzien, A., Schmid, A., Unterkofler, K., Gastl, G., Španěl, P., Smith, D. C., et al. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/2/026002 · Cited by 141
Self-citationTurner, C., Španěl, P., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/1/002 · Cited by 140
Self-citationHalitosis associated volatiles in breath of healthy subjects
den Velde, S. V., Quirynen, M., hee, P. V., & van Steenberghe, D. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.02.048 · Cited by 138
Smith, D. C., & Španěl, P. (1996) · International Reviews in Physical Chemistry · doi:10.1080/01442359609353183 · Cited by 135
Self-citationTurner, C., Parekh, B. K., Walton, C., Španěl, P., Smith, D. C., & Evans, M. L. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3402 · Cited by 135
Self-citationAllardyce, R. A., Langford, V. S., Hill, A. L., & Murdoch, D. R. (2005) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2005.09.003 · Cited by 130
Volatile metabolites in the exhaled breath of healthy volunteers: their levels and distributions
Smith, D. C., Turner, C., & Španěl, P. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/014004 · Cited by 127
Self-citationAcetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4–83 years
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/011001 · Cited by 116
Self-citationŠpaněl, P., & Smith, D. C. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100042a033 · Cited by 115
Self-citationSmith, D. C., Wang, T., Pysanenko, A., & Španěl, P. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3434 · Cited by 105
Self-citationŠpaněl, P., & Smith, D. C. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.265 · Cited by 104
Self-citationSmith, D. C., Španěl, P., Enderby, B., Lenney, W., Turner, C., & Davies, S. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/4/1/017101 · Cited by 101
Self-citationScotter, J. M., Langford, V. S., Wilson, P. F., McEwan, M. J., & Chambers, S. T. (2005) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2005.02.022 · Cited by 87
Španěl, P., Davies, S., & Smith, D. C. (1998) · Rapid Communications in Mass Spectrometry · Cited by 85
Self-citationSmith, D. C., Wang, T., & Španěl, P. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/301 · Cited by 81
Self-citationA new ‘online’ method to measure increased exhaled isoprene in end‐stage renal failure
Davies, S., Španěl, P., & Smith, D. C. (2001) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/16.4.836 · Cited by 80
Self-citationThe concentration distributions of some metabolites in the exhaled breath of young adults
Španěl, P., Dryahina, K., & Smith, D. C. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/2/026001 · Cited by 78
Self-citationŠpaněl, P., & Smith, D. C. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14031-9 · Cited by 77
Self-citationŠpaněl, P., & Smith, D. C. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046003 · Cited by 75
Self-citationEnderby, B., Lenney, W., Brady, M., Emmett, C., Španěl, P., & Smith, D. C. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/3/036001 · Cited by 74
Self-citationŠpaněl, P., Pavlík, M., & Smith, D. C. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04164-g · Cited by 74
Self-citationSelected Ion Flow Tube Mass Spectrometry for On-Line Trace Gas Analysis in Biology and Medicine
Španěl, P., & Smith, D. C. (2007) · European Journal of Mass Spectrometry · doi:10.1255/ejms.843 · Cited by 74
Self-citationSmith, D. C., Diskin, A. M., Ji, Y., & Španěl, P. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00478-x · Cited by 71
Self-citationSulé-Suso, J., Pysanenko, A., Španěl, P., & Smith, D. C. (2009) · The Analyst · doi:10.1039/b916158a · Cited by 70
Self-citationŠpaněl, P., & Smith, D. C. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00253-7 · Cited by 69
Self-citationSelected ion flow tube mass spectrometry of urine headspace
Smith, D. C., Španěl, P., Holland, T. A., Singari, W. A., & Elder, J. B. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990430)13:8 · Cited by 67
Self-citationSovová, K., Ferus, M., Matulková, I., Španěl, P., Dryahina, K., Dvořák, O., & Civiš, S. (2008) · Molecular Physics · doi:10.1080/00268970802077876 · Cited by 67
Self-citationPysanenko, A., Španěl, P., & Smith, D. C. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046004 · Cited by 65
Self-citationTaboulet, P., Haas, L., Porcher, R., Manamani, J., Fontaine, J.-P., Feugeas, J., & Gautier, J. (2004) · European Journal of Emergency Medicine · doi:10.1097/00063110-200410000-00003 · Cited by 65
Diskin, A. M., Wang, T., Smith, D. C., & Španěl, P. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00662-0 · Cited by 63
Self-citationSmith, D. C., Pysanenko, A., & Španěl, P. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.11.007 · Cited by 62
Self-citationQuantification of hydrogen cyanide in humid air by selected ion flow tube mass spectrometry
Španěl, P., Wang, T., & Smith, D. C. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1566 · Cited by 61
Self-citationŠpaněl, P., & Smith, D. C. (1996) · The Journal of Chemical Physics · doi:10.1063/1.470945 · Cited by 59
Self-citationŠpaněl, P., & Smith, D. C. (1999) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(99)00103-7 · Cited by 58
Self-citationDryahina, K., Smith, D. C., & Španěl, P. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4513 · Cited by 57
Self-citationHryniuk, A., & Ross, B. M. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.02.027 · Cited by 54
Boshier, P. R., Marczin, N., & Hanna, G. B. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.02.008 · Cited by 53
Smith, D. C., Španěl, P., & Jones, J. B. (2000) · Bioresource Technology · doi:10.1016/s0960-8524(00)00034-1 · Cited by 49
Self-citationAcetaldehyde and hexanaldehyde from cultured white cells
Shin, H., Umber, B. J., Meinardi, S., Leu, S., Zaldivar, F. P., Blake, D. R., & Cooper, D. M. (2009) · Journal of Translational Medicine · doi:10.1186/1479-5876-7-31 · Cited by 48
Wang, T., Španěl, P., & Smith, D. C. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.07.022 · Cited by 47
Self-citationDiskin, A. M., Španěl, P., & Smith, D. C. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/314 · Cited by 47
Self-citationŠpaněl, P., Turner, C., Wang, T., Bloor, R. N., & Smith, D. C. (2005) · Physiological Measurement · doi:10.1088/0967-3334/27/2/n01 · Cited by 46
Self-citationŠpaněl, P., Diskin, A. M., Abbott, S. M., Wang, T., & Smith, D. C. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.849 · Cited by 45
Self-citationSmith, D. C., Španěl, P., Thompson, J. M., Rajan, B., Cocker, J., & Rolfe, P. J. (1998) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1998.10389161 · Cited by 44
Self-citationAmmonia release from heated ‘street’ cannabis leaf and its potential toxic effects on cannabis users
Bloor, R. N., Wang, T. S., Španěl, P., & Smith, D. C. (2008) · Addiction · doi:10.1111/j.1360-0443.2008.02281.x · Cited by 44
Self-citationSmith, D. C., Cheng, P., & Španěl, P. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.691 · Cited by 44
Self-citationŠpaněl, P., Wang, T., & Smith, D. C. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00724-8 · Cited by 43
Self-citationAssessment of Rumen Processes by Selected-Ion-Flow-Tube Mass Spectrometric Analysis of Rumen Gases
Dewhurst, R. J., Evans, R. T., Mottram, T. T. F., Španěl, P., & Smith, D. C. (2001) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(01)70176-2 · Cited by 42
Self-citationAlcohol in breath and blood: a selected ion flow tube mass spectrometric study
Wilson, P. F., Freeman, C. G., McEwan, M. J., Milligan, D. B., Allardyce, R. A., & Shaw, G. M. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.244 · Cited by 41
Španěl, P., & Smith, D. C. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.07.021 · Cited by 40
Self-citationNEW MEASUREMENT OF HYDROGEN GAS AND ACETONE VAPOR IN GASES EMANATING FROM HUMAN SKIN
Naitoh, K., Tsuda, T., Nose, K., Kondo, T., Takasu, A., & Hirabayashi, T. (2002) · Instrumentation Science & Technology · doi:10.1081/ci-120013506 · Cited by 39
Dolch, M. E., Frey, L., Hornuß, C., Schmoelz, M., Praun, S., Villinger, J., & Schelling, G. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037010 · Cited by 39
Selected ion flow tube mass spectrometry of exhaled breath condensate headspace
Čáp, P., Dryahina, K., Pehal, F., & Španěl, P. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3685 · Cited by 38
Self-citationSmith, D. C., Engel, B., Diskin, A. M., Španěl, P., & Davies, S. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.6.1295 · Cited by 35
Self-citationSmith, D. C., Pysanenko, A., & Španěl, P. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4016 · Cited by 34
Self-citationJulák, J., Stránská, E., Rosová, V., Geppert, H., Španěl, P., & Smith, D. C. (2005) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2005.06.009 · Cited by 33
Self-citationŠpaněl, P., & Smith, D. C. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00157-4 · Cited by 31
Self-citationl, P. P., & Smith, D. C. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(20000430)14:8<646::aid-rcm926>3.0.co;2-7 · Cited by 31
Self-citationŠpaněl, P., & Smith, D. C. (1999) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14099-x · Cited by 30
Self-citationSpooner, A., Bessant, C., Turner, C., Knobloch, H., & Chambers, M. A. (2009) · The Analyst · doi:10.1039/b905627k · Cited by 30
Smith, D. C., Wang, T., & Španěl, P. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.550 · Cited by 29
Self-citationWang, T., Carroll, W. D., Lenny, W., Boit, P., & Smith, D. C. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2285 · Cited by 29
Self-citationOn‐line analysis of diesel engine exhaust gases by selected ion flow tube mass spectrometry
Smith, D. C., Španěl, P., Dabill, D. W., Cocker, J., & Rajan, B. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1702 · Cited by 27
Self-citationWang, T., Španěl, P., & Smith, D. C. (2008) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.01.002 · Cited by 27
Self-citationSmith, D. C., Pysanenko, A., & Španěl, P. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4481 · Cited by 26
Self-citationSenthilmohan, S. T., Kettle, A. J., McEwan, M. J., Dummer, J. F., Edwards, S. J., Wilson, P. F., & Epton, M. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3418 · Cited by 25
Analytical Methods for Breath Investigation
Ligor, T. (2009) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340802569498 · Cited by 22
Kubišta, J., Španěl, P., Dryahina, K., Workman, C., & Smith, D. C. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2340 · Cited by 22
Self-citationŠpaněl, P., Dryahina, K., & Smith, D. C. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.02.023 · Cited by 22
Self-citationBloor, R. N., Španěl, P., & Smith, D. C. (2006) · Addiction Biology · doi:10.1111/j.1369-1600.2006.00015.x · Cited by 22
Self-citationWang, T., Smith, D. C., & Španěl, P. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.804 · Cited by 21
Self-citationSmith, D. C., Wang, T., Španěl, P., & Bloor, R. N. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/6/001 · Cited by 7
Self-citationEngel, B., Španěl, P., Smith, D. C., Diskin, A. M., & Davies, S. (2004) · PubMed · Cited by 7
Self-citationYou are as you smell: the effect of odor and breath odor on social acceptance
Hirsch, A. R. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/1/017001 · Cited by 3
Cited by
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Metadata
- Authors
- Španěl, P., & Smith, D.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2011-02-17
- Volume
- 30
- Issue
- 2
- Pages
- 236-267
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2105673592
- Cited by
- 336
- References
- 111
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.