Single‐molecule mass spectrometry
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In single‐molecule mass spectrometry, the mass of each ion is measured individually; making it suitable for the analysis of very large, heterogeneous objects that cannot be analyzed by conventional means. A range of single‐molecule mass spectrometry techniques has been developed, including time‐of‐flight with cryogenic detectors, a quadrupole ion trap with optical detection, single‐molecule Fourier transform ion cyclotron resonance, charge detection mass spectrometry, quadrupole ion traps coupled to charge detector plates, and nanomechanical oscillators. In addition to providing information on mass and heterogeneity, these techniques have been used to study impact craters from cosmic dust, monitor the assembly of viruses, elucidate the fluorescence dynamics of quantum dots, and much more. This review focuses on the merits of each of these technologies, their limitations, and their applications. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 36:715–733, 2017
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Currents to Conductors Induced by a Moving Point Charge
Shockley, W. (1938) · Journal of Applied Physics · doi:10.1063/1.1710367 · Cited by 1,300 · cited 2×
“The ability to detect neutral fragments directly, rather than through re-ionization, is a great advantage of using cryogenic detectors in tandem MS experiments, at least for small molecules.”
BackgroundWeighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Dynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194 · cited 2×
“The ability to detect neutral fragments directly, rather than through re-ionization, is a great advantage of using cryogenic detectors in tandem MS experiments, at least for small molecules.”
BackgroundSnijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168 · cited 1×
“Except in rare cases (Snijder et al., 2014), conventional MS requires strict homogeneity to weigh ions in the MDa range.”
Cited by
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“Of final note, charge detection MS (CDMS) has also expanded the range of protein complexes that can be analyzed by MS [58].”
BackgroundHigh-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Paving the way to single-molecule protein sequencing
Restrepo-Pérez, L., Joo, C., & Dekker, C. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0236-6 · Cited by 396
The emerging landscape of single-molecule protein sequencing technologies
Alfaro, J. A., Bohländer, P., Dai, M., Filius, M., Howard, C. J., van Kooten, X. F., Ohayon, S., Pomorski, A., Schmid, S., Aksimentiev, A., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01143-1 · Cited by 351
Wörner, T. P., Snijder, J., Bennett, A., Agbandje-McKenna, M., Makarov, A. A., & Heck, A. J. R. (2020) · Nature Methods · doi:10.1038/s41592-020-0770-7 · Cited by 186
Metadata
- Authors
- Keifer, D. Z., & Jarrold, M. F.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2016-02-12
- Volume
- 36
- Issue
- 6
- Pages
- 715-733
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2272801405
- Cited by
- 96
- References
- 5
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single‐molecule mass spectrometry. https://app.cochat.ai/papers/10.1002/mas.21495
- The paper
- Keifer, D. Z., & Jarrold, M. F. (2017). Single‐molecule mass spectrometry. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.21495
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.