The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Intraoperative microrecordings of the subthalamic nucleus in Parkinson's disease
Open accessAbstract
Microelectrode recordings of single unit neuronal activity were used during stereotactic surgery to define the subthalamic nucleus for chronic deep brain stimulation in the treatment of Parkinson's disease. By using five parallel trajectories, often two to three microelectrodes allow us to recognize subthalamic nucleus (STN) neuronal activity. STN neurons were easily distinguished from cells of the overlying zona incerta and the underlying substantia nigra. During a typical exploratory track, we can observe a very low background noise in the zona incerta and almost complete absence of single cell recording. Penetration of the electrode tip into the STN is characterized by a sudden increase in background activity and single cell activity of spontaneously active neurons. The exit of electrode tip out of the STN corresponds to a decrease in background noise and a loss of single cell activity. Spontaneous neuronal activity increases again when the electrode tips enters the substantia nigra pars reticulata (SNr); however, the activity is less rich than in the STN, indicating a more cell-sparse nucleus. STN neurons are characterized by a mean firing rate of 42.30 +/- 22.00 spikes/sec (mean +/- SD). The STN cells exhibited irregular or bursty discharge pattern. The pattern of single cell activity in the SNr is a more regular tonic activity that can easily be distinguished from the bursting pattern in the STN. The most useful criteria to select a trajectory are (1) the length of an individual trajectory displaying typical STN activity, (2) the bursting pattern of activity, and (3) motor responses typical of the sensorimotor part of the nucleus. In conclusion, microelectrode recording of the subthalamic area improves the accuracy of targeting the STN.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment of tremor in Parkinson’s disease by subthalamic nucleus stimulation
Krack, P., Benazzouz, A., Pollak, P., Limousin, P., Piallat, B., Hoffmann, D., Xie, J., & Benabid, A. (1998) · Movement Disorders · doi:10.1002/mds.870130608 · Cited by 252
Self-citation
Cited by
Circuit Mechanisms of Parkinson’s Disease
McGregor, M. M., & Nelson, A. B. (2019) · Neuron · doi:10.1016/j.neuron.2019.03.004 · Cited by 624
Fear extinction in rats: Implications for human brain imaging and anxiety disorders
Milad, M. R., Rauch, S. L., Pitman, R. K., & Quirk, G. J. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.01.008 · Cited by 597
History, Applications, and Mechanisms of Deep Brain Stimulation
Miocinovic, S., Somayajula, S., Chitnis, S., & Vitek, J. L. (2013) · JAMA Neurology · doi:10.1001/2013.jamaneurol.45 · Cited by 496
Deep brain stimulation in epilepsy with particular reference to the subthalamic nucleus
Chabardès, S., Kahane, P., Minotti, L., Koudsie, A., Hirsch, E., & Benabid, A. (2002) · Epileptic Disorders · doi:10.1684/j.1950-6945.2002.tb00549.x · Cited by 304
Self-citationHigh-density single-unit human cortical recordings using the Neuropixels probe
Chung, J. E., Sellers, K. K., Leonard, M. K., Gwilliams, L., Xu, D., Dougherty, M. E., Kharazia, V., Metzger, S. L., Welkenhuysen, M., Dutta, B., et al. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.007 · Cited by 126
Metadata
- Authors
- Benazzouz, A., Breit, S., Koudsie, A., Pollak, P., Krack, P., & Benabid, A.-L.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2002-03
- Volume
- 17
- Issue
- S3
- Pages
- S145-S149
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2063795240
- Cited by
- 338
- References
- 1
- FWCI
- 5.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative microrecordings of the subthalamic nucleus in Parkinson's disease. https://app.cochat.ai/papers/10.1002/mds.10156
- The paper
- Benazzouz, A., Breit, S., Koudsie, A., Pollak, P., Krack, P., & Benabid, A.-L. (2002). Intraoperative microrecordings of the subthalamic nucleus in Parkinson's disease. Movement Disorders. https://doi.org/10.1002/mds.10156
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.