Diagnosis and treatment of complications related to deep brain stimulation hardware
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Deep brain stimulation is a therapeutic technique increasingly used in the treatment of a variety of neurological, psychiatric, and pain disorders. Although beneficial, it carries the immediate and long‐term risks associated with implanted hardware in the brain parenchyma and subcutaneous tissue. The most common hardware complications include electrode migrations or misplacements, wire fractures, skin erosion, infections, and device malfunction. We systematically reviewed the literature on deep brain stimulation–related complications and propose a diagnostic and therapeutic algorithm. Our aim is to provide a guide for clinicians and medical staff involved in the treatment of patients with deep brain stimulation for rapid recognition and efficient management of these complications. © 2011 Movement Disorder Society
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subthalamic nucleus stimulation in severe obsessive-compulsive disorder
Mallet, L., Polosan, M., Jaafari, N., Baup, N., Welter, M.-L., Fontaine, D., Montcel, S. T. D., Yelnik, J., Chéreau, I., Arbus, C., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708514 · Cited by 965
Deep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279 · cited 2×
“Head banding has been used in the treatment of some patients,(40) but surgical repair of the anchoring system may be required.(18,22,27,62) Seroma around the IPG has been reported in 3.”
BackgroundMethodLong-term results of thalamic deep brain stimulation for essential tremor: Clinical article
Zhang, K., Bhatia, S., Oh, M. Y., Cohen, D., Angle, C., & Whiting, D. (2010) · Journal of Neurosurgery · doi:10.3171/2009.10.jns09371 · Cited by 190
Cited by
The safety and efficacy of thalamic deep brain stimulation in essential tremor: 10 years and beyond
Baizabal-Carvallo, J. F., Kagnoff, M. N., Jimenez-Shahed, J., Fekete, R., & Jankovic, J. (2014) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2013-304943 · Cited by 181
Self-citationLin, H.-C., Pan, H.-C., Lin, S.-H., Lo, Y.-C., Shen, E. T.-H., Liao, L.-D., Liao, P.-H., Chien, Y.-W., Liao, K.-D., Jaw, F.-S., et al. (2016) · Frontiers in Neural Circuits · doi:10.3389/fncir.2015.00087 · Cited by 29
Deep brain stimulation for psychiatric diseases: what are the risks?
Saleh, C., & Fontaine, D. (2015) · Current Psychiatry Reports · doi:10.1007/s11920-015-0565-1 · Cited by 30
Metadata
- Authors
- Baizabal Carvallo, J. F., Simpson, R., & Jankovic, J.
- Venue
- Movement Disorders
- Publisher
- Wiley
- Published
- 2011-06-28
- Volume
- 26
- Issue
- 8
- Pages
- 1398-1406
- ISSN
- 0885-3185 (ISSN-L)
- 1531-8257
- OpenAlex
- W2169147129
- Cited by
- 67
- References
- 3
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.