CoChat

Tractography‐Based Ventral Intermediate Nucleus Targeting: Novel Methodology and Intraoperative Validation

Open access
Sammartino, Francesco, Krishna, Vibhor, King, Nicolas Kon Kam, Lozano, Andres M., Schwartz, Michael L., Huang, Yuexi, Hodaie, Mojgan · 2016 · Movement Disorders
Cited by 173

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Background: The ventral intermediate nucleus of the thalamus is not readily visible on structural magnetic resonance imaging. Therefore, a method for its visualization for stereotactic targeting is desirable. Objective: The objective of this study was to define a tractography‐based methodology for the stereotactic targeting of the ventral intermediate nucleus. Methods: The lateral and posterior borders of the ventral intermediate nucleus were defined by tracking the pyramidal tract and medial lemniscus, respectively. A thalamic seed was then created 3 mm medial and anterior to these borders, and its structural connections were analyzed. The application of this method was assessed in an imaging cohort of 14 tremor patients and 15 healthy controls, in which we compared the tractography‐based targeting to conventional targeting. In a separate surgical cohort (3 tremor and 3 tremor‐dominant Parkinson's disease patients), we analyzed the accuracy of this method by correlating it with intraoperative neurophysiology. Results: Tractography of the thalamic seed revealed the tracts corresponding to cerebellar input and motor cortical output fibers. The tractography‐based target was more lateral (12.5 [1.2] mm vs 11.5 mm for conventional targeting) and anterior (8.5 [1.1] mm vs 6.7 [0.3] mm, anterior to the posterior commissure). In the surgical cohort, the Euclidian distance between the ventral intermediate nucleus identified by tractography and the surgical target was 1.6 [1.1] mm. The locations of the sensory thalamus, lemniscus, and pyramidal tracts were concordant within <1 mm between tractography and neurophysiology. Interpretation: The tractography‐based methodology for identification of the ventral intermediate nucleus is accurate and useful. This method may be used to improve stereotactic targeting in functional neurosurgery procedures. © 2016 The Authors. Movement Disorders published by Wiley Periodicals, Inc. on behalf of International Parkinson and Movement Disorder Society

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mds.26633

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 173

Metadata

Authors
Sammartino, F., Krishna, V., King, N. K. K., Lozano, A. M., Schwartz, M. L., Huang, Y., & Hodaie, M.
Venue
Movement Disorders
Publisher
Wiley
Published
2016-05-23
Volume
31
Issue
8
Pages
1217-1225
ISSN
  • 0885-3185 (ISSN-L)
  • 1531-8257
OpenAlex
W2397657821
Cited by
173
References
13
FWCI
11.59
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tractography‐Based Ventral Intermediate Nucleus Targeting: Novel Methodology and Intraoperative Validation. https://app.cochat.ai/papers/10.1002/mds.26633
The paper
Sammartino, F., Krishna, V., King, N. K. K., Lozano, A. M., Schwartz, M. L., Huang, Y., & Hodaie, M. (2016). Tractography‐Based Ventral Intermediate Nucleus Targeting: Novel Methodology and Intraoperative Validation. Movement Disorders. https://doi.org/10.1002/mds.26633

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.