Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study

Abstract

Background Essential tremor is the most common movement disorder and is often refractory to medical treatment. Surgical therapies, using lesioning and deep brain stimulation in the thalamus, have been used to treat essential tremor that is disabling and resistant to medication. Although often effective, these treatments have risks associated with an open neurosurgical procedure. MR-guided focused ultrasound has been developed as a non-invasive means of generating precisely placed focal lesions. We examined its application to the management of essential tremor.Methods Our study was done in Toronto, Canada, between May, 2012, and January, 2013. Four patients with chronic and medication-resistant essential tremor were treated with MR-guided focused ultrasound to ablate tremor-mediating areas of the thalamus. Patients underwent tremor evaluation and neuroimaging at baseline and 1 month and 3 months after surgery. Outcome measures included tremor severity in the treated arm, as measured by the clinical rating scale for tremor, and treatment-related adverse events.Findings Patients showed immediate and sustained improvements in tremor in the dominant hand. Mean reduction in tremor score of the treated hand was 89·4% at 1 month and 81·3% at 3 months. This reduction was accompanied by functional benefits and improvements in writing and motor tasks. One patient had postoperative paraesthesias which persisted at 3 months. Another patient developed a deep vein thrombosis, potentially related to the length of the procedure.Interpretation MR-guided focused ultrasound might be a safe and effective approach to generation of focal intracranial lesions for the management of disabling, medication-resistant essential tremor. If larger trials validate the safety and ascertain the efficacy and durability of this new approach, it might change the way that patients with essential tremor and potentially other disorders are treated.Funding Focused Ultrasound Foundation.

Overview

Integrity signals

Registry

Crossref · 10.1016/s1474-4422(13)70048-6

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Cited by

See all 604

Metadata

Authors
Lipsman, N., Schwartz, M. L., Huang, Y., Lee, L., Sankar, T., Chapman, M., Hynynen, K., & Lozano, A. M.
Affiliations
  • University of Toronto (CA)
  • Sunnybrook Health Science Centre (CA)
  • Sunnybrook Research Institute (CA)
  • University of Alberta (CA)
Venue
The Lancet Neurology
Publisher
Elsevier BV
Published
2013-05
Volume
12
Issue
5
Pages
462-468
ISSN
1474-4422 (ISSN-L)
OpenAlex
W2131979090
Cited by
604
References
30
Citations by year
2026: 15 · 2025: 39 · 2024: 45 · 2023: 35 · 2022: 24 · 2021: 53 · 2020: 50 · 2019: 57 · 2018: 75 · 2017: 57 · 2016: 51 · 2015: 39 · 2014: 44 · 2013: 18
FWCI
32.18
Type
journal article
Language
en
Open access
closed
Locations
  • The Lancet Neurology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
  • Social Sciences › Psychology › Clinical Psychology › Obsessive-Compulsive Spectrum Disorders
Keywords
essential tremor, MR-guided focused ultrasound, thalamotomy, thalamus, focal brain lesions, non-invasive neurosurgery, tremor severity, deep vein thrombosis
MeSH terms
Aged, Canada, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Thalamus, Treatment Outcome, Neurosurgical Procedures, Essential Tremor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study. https://app.cochat.ai/papers/10.1016/s1474-4422(13)70048-6
The paper
Lipsman, N., Schwartz, M. L., Huang, Y., Lee, L., Sankar, T., Chapman, M., Hynynen, K., & Lozano, A. M. (2013). MR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study. The Lancet Neurology. https://doi.org/10.1016/s1474-4422(13)70048-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.