Physiologic tremor and microsurgery
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Physiologic tremor hampers the ability of students to learn microsurgical technique. An understanding of normal tremor both as to origin and methods of control would be of help. Physiological tremor arises from both mechanical and neuromuscular sources and is made worse by a number of factors. The “size principle of motoneuron recruitment” is an important physiologic consideration, and the use of biofeedback techniques enables the student to confirm his understanding of the principle. Knowledge of the factors which aggravate physiological tremor allows the microsurgeon to control his own tremor both in the laboratory and in the operating room.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most familiar type of erroneous movement affecting micromanipulation is hand tremor [2].”
From Active tremor compensation in microsurgery (2005) · cites this paper as [2]
In the citing paper
“and average rms error reduction of 30% with respect to an offline estimate of the tremor-free component of motion.”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
In the citing paper
“The WFLC is an adaptive algorithm that estimates tremor using a dynamic sinusoidal model, estimating its time-varying frequency, amplitude, and phase online.”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
In the citing paper
“Active canceling of physiological tremor using this algorithm has been demonstrated using a 1-dof instrument prototype.”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
In the citing paper
“In 25 tests on hand motion recorded from eye surgeons, this technique yielded average rms amplitude reduction of 69% in the 6-16 Hz band”
From Active tremor compensation in microsurgery (2005) · cites this paper as [17]
Citations
Cites
The orderly recruitment of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010192 · Cited by 920
The relation between integrated action potentials in a human muscle and its isometric tension
Lippold, O. C. J. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004763 · Cited by 653
The contractile properties of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010087 · Cited by 476
Neurophysiological Basis of Normal and Abnormal Motor Activities.
(1968) · Archives of Neurology · doi:10.1001/archneur.1968.00480040114016 · Cited by 405
Fatigue of maintained voluntary muscle contraction in man
Stephens, J. A., & Taylor, A. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009691 · Cited by 320
Neuronal mechanisms underlying physiological tremor
Allum, J. H., Dietz, V., & Freund, H. J. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.3.557 · Cited by 309
Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor
Elble, R. J., & Randall, J. E. (1976) · Journal of Neurophysiology · doi:10.1152/jn.1976.39.2.370 · Cited by 300
Neurophysiology Studied in Man
GILMAN, S. (1973) · Neurology · doi:10.1212/wnl.23.10.1140 · Cited by 298
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
Mechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
Research works printed but not linked: 6
- Marsden CD, 1978, The mechanisms of physiological tremor and their significance for pathological tremors, Prog Clin Neurophysio, 5, 1
- Marshall J, 1968, Tremor, Handbook Clin Neurol, 6, 809
- Rack PMH, 1978, Mechanical and reflex factors in human tremor, Prog Clin Neurophysio, 5, 17
- Dietrichson P, 1978, Quantitation of tremor in man, Prog Clin Neurophysio, 5, 90
- Henneman E, 1981, The size principle of motoneuron recruitment. Motor unit types, recruitment and plasticity in health and disease, Prog Clin Neurophysiol, 19, 26
- Stetson RH, 1935, The coordination of simple skilled movements, Arch Neerl Physio, 20, 177
Cited by
First-in-human study of the safety and viability of intraocular robotic surgery
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0248-4 · Cited by 231
“Safety was demonstrated in two procedures: (1) by using a sharp metallic tip to lift a membrane from the inner surface of the retina (with the z axis limiter engaged to limit retinal touch), and (2) by using the z axis control to advance a fine cannula through the retina into the subretinal space, therefore allowing c…”
Characteristics of hand motion of eye surgeons
Riviere, C. N., Rader, R. S., & Khosla, P. K. (2002) · Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136) · doi:10.1109/iembs.1997.757046 · Cited by 98
Effects of short-term exercise training on signs and symptoms of generalized anxiety disorder
Herring, M. P., Jacob, M. L., Suveg, C., & O’Connor, P. J. (2011) · Mental Health and Physical Activity · doi:10.1016/j.mhpa.2011.07.002 · Cited by 93
Veluvolu, K. C., & Ang, W. T. (2010) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.340 · Cited by 83
A study of instrument motion in retinal microsurgery
Riviere, C. N., & Jensen, P. S. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.900667 · Cited by 70
“The scarcity of data is exacerbated by the fact that those studies that have been done, e.g., studies of physiological tremor and other undesired components of hand movement, have been conducted under laboratory conditions [4,5].”
Background
Metadata
- Authors
- Harwell, R. C., & Ferguson, R. L.
- Corresponding author
- Ferguson, R. Lawrence
- Venue
- Microsurgery
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 4
- Issue
- 3
- Pages
- 187-192
- ISSN
- 0738-1085 (ISSN-L)
- 1098-2752
- OpenAlex
- W1991955181
- Semantic Scholar
- 42605275e9aa5356befa74aa26a96aee6de6f623
- Cited by
- 131
- References
- 42
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 5 · 2023: 3 · 2022: 5 · 2021: 5 · 2020: 3 · 2019: 7 · 2018: 10 · 2017: 1 · 2016: 4 · 2015: 6 · 2014: 3 · 2013: 4 · 2012: 7
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Microsurgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Social Sciences › Education › Innovations in Medical Education
- Keywords
- physiological tremor, size principle, motoneuron recruitment, biofeedback, tremor control
- MeSH terms
- Biomechanical Phenomena, Electromyography, Fatigue, Hand, Humans, Microsurgery, Motor Neurons, Muscles, Stress, Psychological, Surgical Procedures, Operative, Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiologic tremor and microsurgery. https://app.cochat.ai/papers/10.1002/micr.1920040310
- The paper
- Harwell, R. C., & Ferguson, R. L. (1983). Physiologic tremor and microsurgery. Microsurgery. https://doi.org/10.1002/micr.1920040310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.