Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 359

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Quality assurance for image‐guided radiation therapy utilizing CT‐based technologies: A report of the AAPM TG‐179

Open access
Bissonnette, Jean‐Pierre, Balter, Peter A., Dong, Lei, Langen, Katja M., Lovelock, D. Michael, Miften, Moyed, Moseley, Douglas J., Pouliot, Jean, Sonke, Jan‐Jakob, Yoo, Sua·2012·Medical Physics

Abstract

Purpose: Commercial CT‐based image‐guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensure patient safety and patient treatment fidelity for such systems. Methods: The AAPM TG‐179 reviews clinical implementation and quality assurance aspects for commercially available CT‐based IGRT, each with their unique capabilities and underlying physics. The systems described are kilovolt and megavolt cone‐beam CT, fan‐beam MVCT, and CT‐on‐rails. A summary of the literature describing current clinical usage is also provided. Results: This report proposes a generic quality assurance program for CT‐based IGRT systems in an effort to provide a vendor‐independent program for clinical users. Published data from long‐term, repeated quality control tests form the basis of the proposed test frequencies and tolerances. Conclusion: A program for quality control of CT‐based image‐guidance systems has been produced, with focus on geometry, image quality, image dose, system operation, and safety. Agreement and clarification with respect to reports from the AAPM TG‐101, TG‐104, TG‐142, and TG‐148 has been addressed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3690466

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Cited by

See all 359

Metadata

Authors
Bissonnette, J., Balter, P. A., Dong, L., Langen, K. M., Lovelock, D. M., Miften, M., Moseley, D. J., Pouliot, J., Sonke, J., & Yoo, S.
Venue
Medical Physics
Publisher
Wiley
Published
2012-03-20
Volume
39
Issue
4
Pages
1946-1963
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2094921347
Cited by
359
References
53
FWCI
17.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality assurance for image‐guided radiation therapy utilizing CT‐based technologies: A report of the AAPM TG‐179. https://app.cochat.ai/papers/10.1118/1.3690466
The paper
Bissonnette, J., Balter, P. A., Dong, L., Langen, K. M., Lovelock, D. M., Miften, M., Moseley, D. J., Pouliot, J., Sonke, J., & Yoo, S. (2012). Quality assurance for image‐guided radiation therapy utilizing CT‐based technologies: A report of the AAPM TG‐179. Medical Physics. https://doi.org/10.1118/1.3690466

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.