Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Automatic segmentation of the clinical target volume and organs at risk in the planning CT for rectal cancer using deep dilated convolutional neural networks

Men, Kuo, Dai, Jianrong, Li, Yexiong·2017·Medical Physics

Abstract

Purpose: Delineation of the clinical target volume (CTV) and organs at risk (OAR s) is very important for radiotherapy but is time‐consuming and prone to inter‐observer variation. Here, we proposed a novel deep dilated convolutional neural network (DDCNN)‐based method for fast and consistent auto‐segmentation of these structures. Methods: Our DDCNN method was an end‐to‐end architecture enabling fast training and testing. Specifically, it employed a novel multiple‐scale convolutional architecture to extract multiple‐scale context features in the early layers, which contain the original information on fine texture and boundaries and which are very useful for accurate auto‐segmentation. In addition, it enlarged the receptive fields of dilated convolutions at the end of networks to capture complementary context features. Then, it replaced the fully connected layers with fully convolutional layers to achieve pixel‐wise segmentation. We used data from 278 patients with rectal cancer for evaluation. The CTV and OAR s were delineated and validated by senior radiation oncologists in the planning computed tomography (CT) images. A total of 218 patients chosen randomly were used for training, and the remaining 60 for validation. The Dice similarity coefficient (DSC) was used to measure segmentation accuracy. Results: Performance was evaluated on segmentation of the CTV and OAR s. In addition, the performance of DDCNN was compared with that of U‐Net. The proposed DDCNN method outperformed the U‐Net for all segmentations, and the average DSC value of DDCNN was 3.8% higher than that of U‐Net. Mean DSC values of DDCNN were 87.7% for the CTV, 93.4% for the bladder, 92.1% for the left femoral head, 92.3% for the right femoral head, 65.3% for the intestine, and 61.8% for the colon. The test time was 45 s per patient for segmentation of all the CTV, bladder, left and right femoral heads, colon, and intestine. We also assessed our approaches and results with those in the literature: our system showed superior performance and faster speed. Conclusions: These data suggest that DDCNN can be used to segment the CTV and OAR s accurately and efficiently. It was invariant to the body size, body shape, and age of the patients.DDCNN could improve the consistency of contouring and streamline radiotherapy workflows.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.12602

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 298

Metadata

Authors
Men, K., Dai, J., & Li, Y.
Venue
Medical Physics
Publisher
Wiley
Published
2017-10-28
Volume
44
Issue
12
Pages
6377-6389
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2757454662
Cited by
298
References
16
FWCI
11.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.