CoChat

Deep learning for patient‐specific quality assurance: Identifying errors in radiotherapy delivery by radiomic analysis of gamma images with convolutional neural networks

Nyflot, Matthew J., Thammasorn, Phawis, Wootton, Landon S., Ford, Eric C., Chaovalitwongse, W. Art · 2019 · Medical Physics
Cited by 130

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Purpose: Patient‐specific quality assurance (QA) for intensity‐modulated radiation therapy (IMRT) is a ubiquitous clinical procedure, but conventional methods have often been criticized as being insensitive to errors or less effective than other common physics checks. Recently, there has been interest in the application of radiomics, quantitative extraction of image features, to radiotherapy QA. In this work, we investigate a deep learning approach to classify the presence or absence of introduced radiotherapy treatment delivery errors from patient‐specific QA. Methods: Planar dose maps from 186 IMRT beams from 23 IMRT plans were evaluated. Each plan was transferred to a cylindrical phantom CT geometry. Three sets of planar doses were exported from each plan corresponding to (a) the error‐free case, (b) a random multileaf collimator (MLC) error case, and (c) a systematic MLC error case. Each plan was delivered to the electronic portal imaging device (EPID), and planned and measured doses were used to calculate gamma images in an EPID dosimetry software package (for a total of 558 gamma images). Two radiomic approaches were used. In the first, a convolutional neural network with triplet learning was used to extract image features from the gamma images. In the second, a handcrafted approach using texture features was used. The resulting metrics from both approaches were input into four machine learning classifiers (support vector machines, multilayer perceptrons, decision trees, and k‐nearest‐neighbors) in order to determine whether images contained the introduced errors. Two experiments were considered: the two‐class experiment classified images as error‐free or containing any MLC error, and the three‐class experiment classified images as error‐free, containing a random MLC error, or containing a systematic MLC error. Additionally, threshold‐based passing criteria were calculated for comparison. Results: In total, 303 gamma images were used for model training and 255 images were used for model testing. The highest classification accuracy was achieved with the deep learning approach, with a maximum accuracy of 77.3% in the two‐class experiment and 64.3% in the three‐class experiment. The performance of the handcrafted approach with texture features was lower, with a maximum accuracy of 66.3% in the two‐class experiment and 53.7% in the three‐class experiment. Variability between the results of the four machine learning classifiers was lower for the deep learning approach vs the texture feature approach. Both radiomic approaches were superior to threshold‐based passing criteria. Conclusions: Deep learning with convolutional neural networks can be used to classify the presence or absence of introduced radiotherapy treatment delivery errors from patient‐specific gamma images. The performance of the deep learning network was superior to a handcrafted approach with texture features, and both radiomic approaches were better than threshold‐based passing criteria. The results suggest that radiomic QA is a promising direction for clinical radiotherapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13338

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Nyflot, M. J., Thammasorn, P., Wootton, L. S., Ford, E. C., & Chaovalitwongse, W. A.
Venue
Medical Physics
Publisher
Wiley
Published
2018-12-28
Volume
46
Issue
2
Pages
456-464
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2905098610
Cited by
130
References
5
FWCI
12.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.