CoChat

Ultrasound prostate segmentation based on multidirectional deeply supervised V‐Net

Open access
Lei, Yang, Tian, Sibo, He, Xiuxiu, Wang, Tonghe, Wang, Bo, Patel, Pretesh, Jani, Ashesh B., Mao, Hui, Curran, Walter J., Liu, Tian, Yang, Xiaofeng · 2019 · Medical Physics
Cited by 129

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Purpose: Transrectal ultrasound (TRUS) is a versatile and real‐time imaging modality that is commonly used in image‐guided prostate cancer interventions (e.g., biopsy and brachytherapy). Accurate segmentation of the prostate is key to biopsy needle placement, brachytherapy treatment planning, and motion management. Manual segmentation during these interventions is time‐consuming and subject to inter‐ and intraobserver variation. To address these drawbacks, we aimed to develop a deep learning‐based method which integrates deep supervision into a three‐dimensional (3D) patch‐based V‐Net for prostate segmentation. Methods and materials: We developed a multidirectional deep‐learning‐based method to automatically segment the prostate for ultrasound‐guided radiation therapy. A 3D supervision mechanism is integrated into the V‐Net stages to deal with the optimization difficulties when training a deep network with limited training data. We combine a binary cross‐entropy (BCE) loss and a batch‐based Dice loss into the stage‐wise hybrid loss function for a deep supervision training. During the segmentation stage, the patches are extracted from the newly acquired ultrasound image as the input of the well‐trained network and the well‐trained network adaptively labels the prostate tissue. The final segmented prostate volume is reconstructed using patch fusion and further refined through a contour refinement processing. Results: Forty‐four patients' TRUS images were used to test our segmentation method. Our segmentation results were compared with the manually segmented contours (ground truth). The mean prostate volume Dice similarity coefficient (DSC), Hausdorff distance (HD), mean surface distance (MSD), and residual mean surface distance (RMSD) were 0.92 ± 0.03, 3.94 ± 1.55, 0.60 ± 0.23, and 0.90 ± 0.38 mm, respectively. Conclusion: We developed a novel deeply supervised deep learning‐based approach with reliable contour refinement to automatically segment the TRUS prostate, demonstrated its clinical feasibility, and validated its accuracy compared to manual segmentation. The proposed technique could be a useful tool for diagnostic and therapeutic applications in prostate cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13577

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 129

Metadata

Authors
Lei, Y., Tian, S., He, X., Wang, T., Wang, B., Patel, P., Jani, A. B., Mao, H., Curran, W. J., Liu, T., & Yang, X.
Venue
Medical Physics
Publisher
Wiley
Published
2019-05-29
Volume
46
Issue
7
Pages
3194-3206
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2944109339
Cited by
129
References
3
FWCI
8.27
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound prostate segmentation based on multidirectional deeply supervised V‐Net. https://app.cochat.ai/papers/10.1002/mp.13577
The paper
Lei, Y., Tian, S., He, X., Wang, T., Wang, B., Patel, P., Jani, A. B., Mao, H., Curran, W. J., Liu, T., & Yang, X. (2019). Ultrasound prostate segmentation based on multidirectional deeply supervised V‐Net. Medical Physics. https://doi.org/10.1002/mp.13577

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.