CoChat

Report on G4‐Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Open access
Arce, P., Bolst, D., Bordage, M.‐C., Brown, J. M. C., Cirrone, P., Cortés‐Giraldo, M. A., Cutajar, D., Cuttone, G., Desorgher, L., Dondero, P., Dotti, A., Faddegon, B., Fedon, C., Guatelli, S., Incerti, S., Ivanchenko, V., Konstantinov, D., Kyriakou, I., Latyshev, G., Le, A., Mancini‐Terracciano, C., Maire, M., Mantero, A., Novak, M., Omachi, C., Pandola, L., Perales, A., Perrot, Y., Petringa, G., Quesada, J. M., Ramos‐Méndez, J., Romano, F., Rosenfeld, A. B., Sarmiento, L. G., Sakata, D., Sasaki, T., Sechopoulos, I., Simpson, E. C., Toshito, T., Wright, D. H. · 2021 · Medical Physics
Cited by 187

The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.

Abstract

Background: Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro‐ and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. Aims: To respond to these needs, we developed G4‐Med, a benchmarking and regression testing system of Geant4 for medical physics. Materials and Methods: G4‐Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4‐Med are executed on the CERN computing infrastructure via the use of the geant‐val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. Results: This paper describes the tests included in G4‐Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. Discussion: Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics. Conclusion: The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.14226

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 64 references

Metadata

Authors
Arce, P., Bolst, D., Bordage, M. ‐., Brown, J. M. C., Cirrone, P., Cortés‐Giraldo, M. A., Cutajar, D., Cuttone, G., Desorgher, L., Dondero, P., Dotti, A., Faddegon, B., Fedon, C., Guatelli, S., Incerti, S., Ivanchenko, V., Konstantinov, D., Kyriakou, I., Latyshev, G., Le, A., Mancini‐Terracciano, C., Maire, M., Mantero, A., Novak, M., Omachi, C., Pandola, L., Perales, A., Perrot, Y., Petringa, G., Quesada, J. M., Ramos‐Méndez, J., Romano, F., Rosenfeld, A. B., Sarmiento, L. G., Sakata, D., Sasaki, T., Sechopoulos, I., Simpson, E. C., Toshito, T., & Wright, D. H.
Venue
Medical Physics
Publisher
Wiley
Published
2020-12-12
Volume
48
Issue
1
Pages
19-56
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W3022257328
Cited by
187
References
64
FWCI
15.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Report on G4‐Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group. https://app.cochat.ai/papers/10.1002/mp.14226
The paper
Arce, P., Bolst, D., Bordage, M. ‐., Brown, J. M. C., Cirrone, P., Cortés‐Giraldo, M. A., Cutajar, D., Cuttone, G., Desorgher, L., Dondero, P., Dotti, A., Faddegon, B., Fedon, C., Guatelli, S., Incerti, S., Ivanchenko, V., Konstantinov, D., Kyriakou, I., Latyshev, G., . . . Wright, D. H. (2021). Report on G4‐Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group. Medical Physics. https://doi.org/10.1002/mp.14226

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.