The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Postacquisition suppression of large‐vessel BOLD signals in high‐resolution fMRI
Abstract
Large‐vessel BOLD contamination is a serious impediment to localization of neural activity in high‐resolution fMRI studies. A new method is presented which estimates and removes the fraction of BOLD signal that arises from oriented vessels, such as cerebral and pial veins in a voxel, by measuring their influence on the phase angle of the complex valued fMRI time series. A maximum likelihood estimator based on a linear least‐squares fit of the BOLD signal phase to the BOLD signal magnitude in a voxel is shown to efficiently suppress the BOLD effect from these larger veins, whose activation is not well colocalized with the neural response. In high‐resolution in vivo fMRI data at 4 T, it is estimated that the method is sensitive to the phase changes in the cerebral, larger intracortical, and pial veins. The technique requires no special pulse sequence modifications or acquisition strategies, and is computationally fast and intrinsically robust. Magn Reson Med 47:1–9, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Cited by
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Yacoub, E., Shmuel, A., Logothetis, N., & Uğurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.020 · Cited by 308
Martin, R. E., MacIntosh, B. J., Smith, R. C., Barr, A. M., Stevens, T. K., Gati, J. S., & Menon, R. S. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01144.2003 · Cited by 275
Self-citation
Metadata
- Authors
- Menon, R. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-12-20
- Volume
- 47
- Issue
- 1
- Pages
- 1-9
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2025836502
- Cited by
- 214
- References
- 1
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Postacquisition suppression of large‐vessel BOLD signals in high‐resolution fMRI. https://app.cochat.ai/papers/10.1002/mrm.10041
- The paper
- Menon, R. S. (2002). Postacquisition suppression of large‐vessel BOLD signals in high‐resolution fMRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.