Relationships between diffusion tensor and q‐space MRI†
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Fundamental relationships between diffusion tensor (DT) and 3D q‐space MRI are derived which establish conditions when these two complementary MR methods are equivalent. It is shown that the displacement distribution measured by q‐space MRI in both the large displacement (i.e., large r) and the long‐wavelength (i.e., small q) limits is the same 3D Gaussian displacement distribution assumed in DT‐MRI. In these limiting cases,q‐space MR yields a dispersion tensor that is identical to the effective DT,D, measured in DT‐MRI. An experiment is then proposed to measure D using q‐space methods. These findings establish that the effective DT, measured in DT‐MRI, characterizes molecule motions on a coarse length‐scale. Finally, the feasibility of and requirements for performing 3D q‐space MRI on a clinical scanner are considered. Magn Reson Med 47:392–397, 2002. Published 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 2×
“[8] and [9] into Eq.”
BackgroundSelf-citationDiffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Self-citation
Cited by
About “axial” and “radial” diffusivities
Wheeler‐Kingshott, C. A. M., & Cercignani, M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21965 · Cited by 885
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
“…distribution adequately describes the random motion of water molecules in brain tissue (both gray and white matter) only at low b or q values (Basser, 2002), so that over that range of b (or q) values, the description of the diffusion process using the Stejskal – Tanner equation is…”
BackgroundMethodInfluentialSelf-citation“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Self-citationAssaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
Self-citationNTU-90: A high angular resolution brain atlas constructed by q-space diffeomorphic reconstruction
Yeh, F.-C., & Tseng, W.-Y. I. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.021 · Cited by 507
Metadata
- Authors
- Basser, P. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-01-23
- Volume
- 47
- Issue
- 2
- Pages
- 392-397
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2166496643
- Cited by
- 148
- References
- 3
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationships between diffusion tensor and q‐space MRI†. https://app.cochat.ai/papers/10.1002/mrm.10052
- The paper
- Basser, P. J. (2002). Relationships between diffusion tensor and q‐space MRI†. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.