Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

23Na MRI accurately measures fixed charge density in articular cartilage

Open access
Shapiro, Erik M., Borthakur, Arijitt, Gougoutas, Alexander, Reddy, Ravinder·2002·Magnetic Resonance in Medicine

Abstract

One of the initiating steps of osteoarthritis is the loss of proteoglycan (PG) molecules from the cartilage matrix. One method for assessing cartilage integrity, therefore, is to measure the PG content or fixed charge density (FCD) of cartilage. This report shows the feasibility of calculating FCD by 23 Na MRI and introduces MRI protocols for human studies, in vivo. 23 Na MRI was used to measure the sodium concentration inside bovine patellar cartilage. The sodium concentration was then converted to FCD (mM) by considering ideal Donnan equilibrium. These FCD measurements were compared to FCD measurements obtained through standard dimethylmethylene blue PG assays. There was a high correlation (slope = 0.89, r 2 = 0.81) between the FCD measurements obtained by 23 Na MRI and those obtained by the PG assays. These methods were then employed in quantifying the FCD of articular cartilage of human volunteers in vivo. Two imaging protocols were compared: one using a birdcage coil, the other using a transmit/receive surface coil. Both methodologies gave similar results, with the average sodium concentration of normal human patellar cartilage ranging from ∼240 to 260 mM. This corresponds to FCDs of –158 mM to –182 mM. Magn Reson Med 47:284–291, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10054

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 261

Metadata

Authors
Shapiro, E. M., Borthakur, A., Gougoutas, A., & Reddy, R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-01-23
Volume
47
Issue
2
Pages
284-291
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2026076082
Cited by
261
References
18
FWCI
7.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 23Na MRI accurately measures fixed charge density in articular cartilage. https://app.cochat.ai/papers/10.1002/mrm.10054
The paper
Shapiro, E. M., Borthakur, A., Gougoutas, A., & Reddy, R. (2002). 23Na MRI accurately measures fixed charge density in articular cartilage. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10054

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.