Detection of lymph node metastases by contrast‐enhanced MRI in an experimental model
The DOI matches its Crossref record.
Abstract
Lymph node size, the accumulation of a nodal lymphotrophic contrast agent (LCDIO), and MRI were compared as methods for detecting nodal metastases in an experimental murine model. Lymph node metastases (B16‐F1 melanoma expressing green fluorescent protein (GFP) and C57BL/6 mice) were generated to obtain a wide spectrum of nodes, including normal nodes and nodes bearing micrometastases, small metastases, or large metastases. Nodal uptake of LCDIO was measured using 111 Indium‐labeled LCDIO and was found to be lower in micrometastastic nodes (4.20 ± 1.4%ID/gm) than in normal nodes (8.60 ± 0.22% ID dose/gram, P < 0.005). Nodal tumor burden was quantified from the amount of GFP present in nodes measured using the Western blot method, and was found to correlate with the decrease of LCDIO uptake. By MRI, nodes bearing small and large metastases contained regions of high signal intensity (SI) that corresponded to the visual pattern of tumor in nodes. Micrometastatic nodes were distinguishable from normal nodes based on a diffuse pattern of inhomogeneous SI. The signal‐to‐background ratio (SBR) of normal nodes (0.0112 ± 0.0061) was different from micrometastatic nodes (0.179 ± 0.080, P < 0.00046) and nodes bearing small metastases (0.723 ± 0.269, P < 0.00013), with high degrees of significance. Magn Reson Med 47:292–297, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Self-citationShedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Self-citationImaging macrophages with nanoparticles
Weissleder, R., Nahrendorf, M., & Pittet, M. J. (2014) · Nature Materials · doi:10.1038/nmat3780 · Cited by 809
Application of Nanotechnology in Cancer Therapy and Imaging
Wang, X., Yang, L., Chen, Z., & Shin, D. M. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0003 · Cited by 700
Nanotechnology and its use in imaging and drug delivery (Review)
Sim, S., & Wong, N. (2021) · Biomedical Reports · doi:10.3892/br.2021.1418 · Cited by 454
Metadata
- Authors
- Wunderbaldinger, P., Josephson, L., Bremer, C., Moore, A., & Weissleder, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-01-23
- Volume
- 47
- Issue
- 2
- Pages
- 292-297
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2037968286
- Cited by
- 80
- References
- 0
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of lymph node metastases by contrast‐enhanced MRI in an experimental model. https://app.cochat.ai/papers/10.1002/mrm.10068
- The paper
- Wunderbaldinger, P., Josephson, L., Bremer, C., Moore, A., & Weissleder, R. (2002). Detection of lymph node metastases by contrast‐enhanced MRI in an experimental model. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.