Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 240

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Respiration‐induced B0fluctuations and their spatial distribution in the human brain at 7 Tesla

Open access
Van de Moortele, Pierre‐François, Pfeuffer, Josef, Glover, Gary H., Ugurbil, Kamil, Hu, Xiaoping·2002·Magnetic Resonance in Medicine

Abstract

In functional magnetic resonance imaging (fMRI), it is known that physiological influences such as cardiac pulsation, respiration, and brain motion can induce fluctuations in signal intensity and phase. Some of the mechanisms potentially involved in those phenomena are expected to be amplified at higher magnetic fields. This study addresses the issue of B0 fluctuations induced by susceptibility changes during respiration attributed to movements of chest and diaphragm, and variations in the oxygen concentration. It is demonstrated that respiration‐induced resonance offsets (RIROs) are significant at 7T. Data were acquired with an RF pulse (no gradients), multislice echo‐planar imaging (EPI), and dynamic 3D fast low‐angle shot (3D‐ FLASH) imaging. Three main observations summarize the experimental findings. First, in FIDs measured after a single RF pulse, a RIRO with a large amplitude was consistently detected, although the average amplitude varied between subjects from 1.45 Hz to 4 Hz. Second, in transverse EPI images obtained in the occipital lobe, the RIRO amplitude showed a monotonic increase along the z axis toward the lungs. Third, a more detailed spatial analysis with 3D‐FLASH phase maps revealed that a previously published analytical model can accurately describe the spatial distribution of RIRO. Consequential apparent motions in the EPI series, as well as the implications of slice orientation for correction strategies are discussed. Magn Reson Med 47:888–895, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10145

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 240

Metadata

Authors
Van de Moortele, P., Pfeuffer, J., Glover, G. H., Ugurbil, K., & Hu, X.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-04-22
Volume
47
Issue
5
Pages
888-895
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2155220364
Cited by
240
References
1
FWCI
5.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Respiration‐induced B0fluctuations and their spatial distribution in the human brain at 7 Tesla. https://app.cochat.ai/papers/10.1002/mrm.10145
The paper
Van de Moortele, P., Pfeuffer, J., Glover, G. H., Ugurbil, K., & Hu, X. (2002). Respiration‐induced B0fluctuations and their spatial distribution in the human brain at 7 Tesla. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10145

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.