Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: Effects of magnetic field variation
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The presence of magnetic background field inhomogeneity (ΔB) may confound quantitative measures of cerebral venous blood volume (vCBV) and cerebral oxygen extraction fraction (MR_OEF) with T‐based methods. The goal of this study was to correct its effect and obtain more accurate estimates of vCBV and MR_OEF. A 3D high‐resolution gradient echo sequence was employed to obtain ΔB maps by two algorithms. The ΔB maps were then used to recover the signal loss in images acquired by a 2D multiecho gradient echo / spin echo sequence. Finally, both quantitative estimates of MR_OEF and vCBV were obtained from the ΔB‐ corrected 2D multiecho gradient echo / spin echo images. A total of 12 normal subjects were studied. An overestimated vCBV was observed in the brain (4.29 ± 0.78%) prior to ΔB correction, while the measured vCBV was substantially reduced after ΔB correction. Whole brain vCBV of 2.97 ± 0.44% and 2.68 ± 0.47% were obtained by the two different ΔB correction methods, in excellent agreement with the reported results in the literature. Furthermore, when MR_OEF was compared with and without ΔB correction, no significant differences (P = 0.467) were observed. The ability to simultaneously obtain vCBV and MR_OEF noninvasively may have profound clinical implications for the studies of cerebrovascular disease. Magn Reson Med 47:958–966, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Study design in fMRI: Basic principles
Amaro, E., & Barker, G. J. (2006) · Brain and Cognition · doi:10.1016/j.bandc.2005.11.009 · Cited by 517
He, X., & Yablonskiy, D. A. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21108 · Cited by 396
The physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Metadata
- Authors
- An, H., & Lin, W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-04-22
- Volume
- 47
- Issue
- 5
- Pages
- 958-966
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2047541454
- Cited by
- 126
- References
- 2
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.