The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Image distortion correction in EPI: Comparison of field mapping with point spread function mapping
Open accessAbstract
Echo‐planar imaging (EPI) can provide rapid imaging by acquiring a complete k‐space data set in a single acquisition. However, this approach suffers from distortion effects in geometry and intensity, resulting in poor image quality. The distortions, caused primarily by field inhomogeneities, lead to intensity loss and voxel shifts, the latter of which are particularly severe in the phase‐encode direction. Two promising approaches to correct the distortion in EPI are field mapping and point spread function (PSF) mapping. The field mapping method measures the field distortions and translates these into voxel shifts, which can be used to assign image intensities to the correct voxel locations. The PSF approach uses acquisitions with additional phase‐encoding gradients applied in the x, y, and/or z directions to map the 1D, 2D, or 3D PSF of each voxel. These PSFs encode the spatial information about the distortion and the overall distribution of intensities from a single voxel. The measured image is the convolution of the undistorted density and the PSF. Measuring the PSF allows the distortion in geometry and intensity to be corrected. This work compares the efficacy of these methods with equal time allowed for field mapping and PSF mapping. Magn Reson Med 48:137–146, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Correction for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421
Twieg, D. B. (1983) · Medical Physics · doi:10.1118/1.595331 · Cited by 373
A simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
Compensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
Deichmann, R., Josephs, O., Hutton, C., Corfield, D. R., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.0985 · Cited by 253
Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps
Reber, P. J., Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390223 · Cited by 223
Schneider, E., & Glover, G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180208 · Cited by 221
Measurement of the point spread function in MRI using constant time imaging
Robson, M. D., Gore, J. C., & Constable, R. T. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380509 · Cited by 161
Self-citation3D z-shim method for reduction of susceptibility effects in BOLD fMRI
Glover, G. H. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199908)42:2<290::aid-mrm11>3.0.co;2-n · Cited by 160
Yang, Q., Williams, G. D., Demeure, R., Mosher, T. J., & Smith, M. B. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390310 · Cited by 125
Composite image formation inz-shimmed functional MR imaging
Constable, R. T., & Spencer, D. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<110::aid-mrm15>3.0.co;2-3 · Cited by 119
Self-citation
Cited by
Comparing face patch systems in macaques and humans
Tsao, D. Y., Moeller, S., & Freiwald, W. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0809662105 · Cited by 659
Holland, D., Kuperman, J. M., & Dale, A. M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.044 · Cited by 471
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Zaitsev, M., Hennig, J., & Speck, O. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20261 · Cited by 349
Brain shift in neuronavigation of brain tumors: A review
Gerard, I. J., Kersten-Oertel, M., Petrecca, K., Sirhan, D., Hall, J. A., & Collins, D. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.007 · Cited by 324
Patches of face-selective cortex in the macaque frontal lobe
Tsao, D. Y., Schweers, N., Moeller, S., & Freiwald, W. A. (2008) · Nature Neuroscience · doi:10.1038/nn.2158 · Cited by 286
A Hitchhiker's Guide to Functional Magnetic Resonance Imaging
Soares, J. M., Magalhães, R., Moreira, P. S., Sousa, A., Ganz, E., Sampaio, A., Alves, V., Marques, P., & Sousa, N. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00515 · Cited by 272
Adachi, Y., Osada, T., Sporns, O., Watanabe, T., Matsui, T., Miyamoto, K., & Miyashita, Y. (2012) · Cerebral Cortex · doi:10.1093/cercor/bhr234 · Cited by 211
Neurobiology of culturally common maternal responses to infant cry
Bornstein, M. H., Putnick, D. L., Rigo, P., Esposito, G., Swain, J. E., Suwalsky, J. T. D., Su, X., Du, X., Zhang, K., Cote, L. R., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1712022114 · Cited by 168
Species-specific response to human infant faces in the premotor cortex
Caria, A., de Falco, S., Venuti, P., Lee, S., Esposito, G., Rigo, P., Birbaumer, N., & Bornstein, M. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.068 · Cited by 135
Functional magnetic resonance imaging: A review of methodological aspects and clinical applications
Hennig, J., Speck, O., Koch, M. A., & Weiller, C. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10330 · Cited by 100
Juchem, C., Umesh Rudrapatna, S., Nixon, T. W., & de Graaf, R. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.011 · Cited by 74
Venuti, P., Caria, A., Esposito, G., De Pisapia, N., Bornstein, M. H., & de Falco, S. (2012) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2012.06.011 · Cited by 48
Metadata
- Authors
- Zeng, H., & Constable, R. T.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-06-27
- Volume
- 48
- Issue
- 1
- Pages
- 137-146
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2133455575
- Cited by
- 274
- References
- 14
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.