Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 528

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data

Open access
Alexander, D.C., Barker, G.J., Arridge, S.R.·2002·Magnetic Resonance in Medicine

Abstract

This work details the observation of non‐Gaussian apparent diffusion coefficient (ADC) profiles in multi‐direction, diffusion‐weighted MR data acquired with easily achievable imaging parameters (b≈ 1000 s/mm 2). A technique is described for modeling the profile of the ADC over the sphere, which can capture non‐Gaussian effects that can occur at, for example, intersections of different tissue types or white matter fiber tracts. When these effects are significant, the common diffusion tensor model is inappropriate, since it is based on the assumption of a simple underlying diffusion process, which can be described by a Gaussian probability density function. A sequence of models of increasing complexity is obtained by truncating the spherical harmonic (SH) expansion of the ADC measurements at several orders. Further, a method is described for selection of the most appropriate of these models, in order to describe the data adequately but without overfitting. The combined procedure is used to classify the profile at each voxel as isotropic, anisotropic Gaussian, or non‐Gaussian, each with reference to the underlying probability density function of displacement of water molecules. We use it to show that non‐Gaussian profiles arise consistently in various regions of the human brain where complex tissue structure is known to exist, and can be observed in data typical of clinical scanners. The performance of the procedure developed is characterized using synthetic data in order to demonstrate that the observed effects are genuine. This characterization validates the use of our method as an indicator of pathology that affects tissue structure, which will tend to reduce the complexity of the selected model. Magn Reson Med 48:331–340, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10209

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 528

Metadata

Authors
Alexander, D. C., Barker, G. J., & Arridge, S. R.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-07-31
Volume
48
Issue
2
Pages
331-340
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1984216864
Cited by
528
References
23
FWCI
15.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data. https://app.cochat.ai/papers/10.1002/mrm.10209
The paper
Alexander, D. C., Barker, G. J., & Arridge, S. R. (2002). Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10209

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.