The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data
Open accessAbstract
This work details the observation of non‐Gaussian apparent diffusion coefficient (ADC) profiles in multi‐direction, diffusion‐weighted MR data acquired with easily achievable imaging parameters (b≈ 1000 s/mm 2). A technique is described for modeling the profile of the ADC over the sphere, which can capture non‐Gaussian effects that can occur at, for example, intersections of different tissue types or white matter fiber tracts. When these effects are significant, the common diffusion tensor model is inappropriate, since it is based on the assumption of a simple underlying diffusion process, which can be described by a Gaussian probability density function. A sequence of models of increasing complexity is obtained by truncating the spherical harmonic (SH) expansion of the ADC measurements at several orders. Further, a method is described for selection of the most appropriate of these models, in order to describe the data adequately but without overfitting. The combined procedure is used to classify the profile at each voxel as isotropic, anisotropic Gaussian, or non‐Gaussian, each with reference to the underlying probability density function of displacement of water molecules. We use it to show that non‐Gaussian profiles arise consistently in various regions of the human brain where complex tissue structure is known to exist, and can be observed in data typical of clinical scanners. The performance of the procedure developed is characterized using synthetic data in order to demonstrate that the observed effects are genuine. This characterization validates the use of our method as an indicator of pathology that affects tissue structure, which will tend to reduce the complexity of the selected model. Magn Reson Med 48:331–340, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crank, J. (1956) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,978
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Special Functions of Mathematical Physics
Nikiforov, A. F., & Uvarov, V. B. (1988) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4757-1595-8 · Cited by 2,002
Statistical Methods in Medical Research
Lachenbruch, P. A. (1972) · Technometrics · doi:10.1080/00401706.1972.10488903 · Cited by 1,703
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Pajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Analysis of partial volume effects in diffusion‐tensor MRI
Alexander, A. L., Hasan, K. M., Lazar, M., Tsuruda, J. S., & Parker, D. L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1105 · Cited by 695
Parametrization of Closed Surfaces for 3-D Shape Description
Brechbühler, C., Gerig, G., & Kübler, O. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1013 · Cited by 681
Principles and Application of Self-Diffusion Measurements by Nuclear Magnetic Resonance
KÄRGER, J., PFEIFER, H., & HEINK, W. (1988) · Advances in Magnetic and Optical Resonance · doi:10.1016/b978-0-12-025512-2.50004-x · Cited by 660
Pajevic, S., & Pierpaoli, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<526::aid-mrm15>3.0.co;2-j · Cited by 640
Characterization of anisotropy in high angular resolution diffusion‐weighted MRI
Frank, L. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10156 · Cited by 510
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Theoretical analysis of the effects of noise on diffusion tensor imaging
Anderson, A. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1315 · Cited by 280
Effects of Finite Gradient-Pulse Widths in Pulsed-Field-Gradient Diffusion Measurements
Mitra, P. P., & Halperin, B. I. (1995) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1995.1060 · Cited by 208
Mapping fiber orientation spectra in cerebral white matter with Fourier-transform diffusion MRI
Wedeen, V. J., Reese, T. G., Tuch, D. S., Weigel, M., Dou, J., Weisskoff, R. M., & Chessler, D. (2000) · Cited by 188
High Angular Resolution Diffusion Imaging of the Human Brain
Tuch, D. S. (1999) · Cited by 156
Armitage, P. A., & Bastin, M. E. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1140 · Cited by 47
Cited by
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Self-citationCharacterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Metadata
- Authors
- Alexander, D. C., Barker, G. J., & Arridge, S. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-07-31
- Volume
- 48
- Issue
- 2
- Pages
- 331-340
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1984216864
- Cited by
- 528
- References
- 23
- FWCI
- 15.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.