Abstract

The experiments reported herein are the first MRI investigations of the orientational dependence of T2 relaxation in articular cartilage at microscopic resolution over the 360° angular space. For each of six canine cartilage specimens, 48 independent T2‐weighted proton images were acquired for 12 different specimen orientations. Pixel‐wise monoexponential fits of these proton images produced 12 T2 relaxation images, each with an in‐plane pixel resolution of 13.7 μm. Cartilage T2 as a function of specimen orientation was shown to follow approximately the angular dependence of the nuclear dipole–dipole interaction, with local maxima at approximately 55°, 125°, 235°, and 305°. However, the relative amplitudes of the T2 maxima deviated somewhat from those expected from the dipolar interaction. The amplitudes of these maxima also varied with tissue depth: the largest amplitudes were found in the radial zone, intermediate amplitudes were found in the superficial zone, and there was a continuous decrease in amplitude approaching the transitional zone from the superficial zone above and the radial zone below. We explain the discrepancy between the observed T2 anisotropy and the angular dependence of the dipolar interaction by means of a simple model which considers the average of one isotropic and two anisotropic spin populations—the first being associated with “free” water, and the latter two arising from collagen‐associated waters. We show that even for the “long” T2 components, which arise in multiple‐compartment studies of collagen‐water systems, there appears to be two subpopulations. Each has the same peak value of T2, but the angular dependence of one is shifted in phase by 90° relative to the other by virtue of the fact that each is associated with groups of mutually perpendicular fibrils. Magn Reson Med 48:460–469, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10216

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 218

Metadata

Authors
Xia, Y., Moody, J. B., & Alhadlaq, H.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-08-23
Volume
48
Issue
3
Pages
460-469
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2004775901
Cited by
218
References
0
FWCI
2.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (μMRI) study. https://app.cochat.ai/papers/10.1002/mrm.10216
The paper
Xia, Y., Moody, J. B., & Alhadlaq, H. (2002). Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (μMRI) study. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.