Orientational diffusion reflects fiber structure within a voxel
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Several new MR techniques have been introduced to infer direction through diffusion in multiple nerve fiber bundles within a voxel. To date, however, there has been no physical model reported to evaluate these methodologies and their ability to determine fiber orientation. In this article a model of diffusion analogous to nerve fibers is presented. Diffusion measurements at multiple closely spaced angles of 15° in samples with different fiber orientations are compared with theoretical calculations for restricted diffusion in cylindrical geometry. Orientational diffusion measurements are shown to reflect fiber geometry and theoretical predictions to within 10%. Simulations of fiber crossings within a voxel suggest fiber orientation does not correspond to the direction of the largest measured diffusion coefficient, but theoretical knowledge of signal decay curves can predict the shape of these diffusion coefficient contours for given fiber orientation probabilities. Magn Reson Med 48:454–459, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 1×
“Similar models have been suggested in the literature (23,25).”
ResultSelf-citationAnisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Cited by
Tournier, J.-D., Yeh, C.-H., Calamante, F., Cho, K.-H., Connelly, A., & Lin, C.-P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.002 · Cited by 593
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Özarslan, E., & Mareci, T. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10596 · Cited by 423
Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)
Özarslan, E., Shepherd, T. M., Vemuri, B. C., Blackband, S. J., & Mareci, T. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.024 · Cited by 388
Multi-compartment microscopic diffusion imaging
Kaden, E., Kelm, N. D., Carson, R. P., Does, M. D., & Alexander, D. C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.002 · Cited by 345
Metadata
- Authors
- von dem Hagen, E. A. H., & Henkelman, R. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-08-23
- Volume
- 48
- Issue
- 3
- Pages
- 454-459
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2008221065
- Cited by
- 88
- References
- 4
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.