CoChat

Human erythrocyte ghosts: Exploring the origins of multiexponential water diffusion in a model biological tissue with magnetic resonance

Thelwall, Peter E., Grant, Samuel C., Stanisz, Greg J., Blackband, Stephen J. · 2002 · Magnetic Resonance in Medicine
Cited by 67

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A tissue model composed of erythrocyte ghosts was developed to study the effects of compartmentation on the MR signal acquired from biological tissues. This simple and flexible model offers control over the biophysical parameters that contribute to multicomponent signals arising from cellular systems. Cell density, size, intra‐ and extracellular composition, and membrane permeability can be independently altered. The effects of cell density and cell size on water diffusion properties were assessed. The data demonstrate non‐monoexponential water diffusion in ghost cell suspensions of 17–67% cell density. Data were analysed with the widely employed two‐compartment (biexponential) model, and with a two‐compartment model that accounted for exchange between compartments. Water exchange between the intra‐ and extracellular compartments appeared to be significant over the range of diffusion times studied (7–35 ms). The biexponential fit to the ghost data appeared to be underparameterised as the ADCs and relative fractions of the fast and slow components were dependent on the experimental acquisition parameters, specifically the diffusion time. However, both analysis methods proved effective at tracking changes in the ghost model when it was perturbed. This was demonstrated with cell density variation, cell swelling and shrinkage experiments, and reduction of membrane water permeability using a water channel blocker (pCMBS). We anticipate that this model system could be used to investigate compartmental diffusion effects to simulate a range of pathologies, especially ischemic stroke. Magn Reson Med 48:649–657, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10270

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 67

Metadata

Authors
Thelwall, P. E., Grant, S. C., Stanisz, G. J., & Blackband, S. J.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-09-26
Volume
48
Issue
4
Pages
649-657
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2007162694
Cited by
67
References
2
FWCI
3.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human erythrocyte ghosts: Exploring the origins of multiexponential water diffusion in a model biological tissue with magnetic resonance. https://app.cochat.ai/papers/10.1002/mrm.10270
The paper
Thelwall, P. E., Grant, S. C., Stanisz, G. J., & Blackband, S. J. (2002). Human erythrocyte ghosts: Exploring the origins of multiexponential water diffusion in a model biological tissue with magnetic resonance. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10270

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.