The DOI matches its Crossref record.
Is TrueFISP a gradient‐echo or a spin‐echo sequence?
Open accessAbstract
It is commonly accepted that TrueFISP (balanced FFE, FIESTA) belongs to the class of gradient‐echo (GRE) sequences. GRE sequences are sensitive to dephasing effects of the transverse magnetization between the excitation pulse and echo acquisition, and phase coherence is only established directly after and before excitation pulses. However, an analysis of the phase evolution of transverse magnetization in a TrueFISP experiment shows very close similarities to the echo formation of a spin‐echo (SE) experiment. If dephasing between excitation pulses is below ±π, TrueFISP exhibits a nearly complete refocusing of transverse magnetization at TE = TR/2. Only signals acquired before and after TR/2 show an additional T sensitivity. Magn Reson Med 49:395–397, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Steady-State MR Imaging Sequences: Physics, Classification, and Clinical Applications
Chavhan, G. B., Babyn, P. S., Jankharia, B. G., Cheng, H.-L. M., & Shroff, M. M. (2008) · RadioGraphics · doi:10.1148/rg.284075031 · Cited by 294
Teixeira, R. P. A. G., Malik, S. J., & Hajnal, J. V. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26670 · Cited by 39
Metadata
- Authors
- Scheffler, K., & Hennig, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-01-22
- Volume
- 49
- Issue
- 2
- Pages
- 395-397
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2035519549
- Cited by
- 197
- References
- 0
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is TrueFISP a gradient‐echo or a spin‐echo sequence? https://app.cochat.ai/papers/10.1002/mrm.10351
- The paper
- Scheffler, K., & Hennig, J. (2003). Is TrueFISP a gradient‐echo or a spin‐echo sequence? Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.