A new imaging method has been developed for quantitatively measuring magnetization transfer (MT). It uses a simple inversion recovery sequence, although one with very short (milliseconds) inversion times, and thus can be implemented on clinical imaging systems with little modification to existing pulse sequences. The sequence requires an inversion pulse with a length much longer than T2m (typically 10 μs) and much shorter than T2f (typically tens of ms) and 1/kmf (typically tens of ms), where T2m and T2f are the transverse relaxation times of the immobile macromolecular and free water protons, respectively, and kmf is the rate of MT between these populations. The resultant NMR signal is sensitive to MT when this inversion pulse affects the mobile and immobile proton pools to different degrees and by appropriate analysis of the signals obtained for different inversion times, quantitative information can be derived on the macromolecular content and exchange rates within the sample. The method has been used in conjunction with echo planar imaging to produce maps of the spatial distribution of the macromolecular content and MT rate in cross‐linked bovine serum albumin. Comparisons between this method and other quantitative MT techniques are discussed. Magn Reson Med 49:501–505, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
The current state-of-the-art of spinal cord imaging: Methods
Stroman, P. W., Wheeler-Kingshott, C., Bacon, M., Schwab, J. M., Bosma, R., Brooks, J., Cadotte, D., Carlstedt, T., Ciccarelli, O., Cohen-Adad, J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.124 · Cited by 334
Metadata
- Authors
- Gochberg, D. F., & Gore, J. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-03
- Volume
- 49
- Issue
- 3
- Pages
- 501-505
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2103632755
- Cited by
- 139
- References
- 1
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative imaging of magnetization transfer using an inversion recovery sequence. https://app.cochat.ai/papers/10.1002/mrm.10386
- The paper
- Gochberg, D. F., & Gore, J. C. (2003). Quantitative imaging of magnetization transfer using an inversion recovery sequence. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.