Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS)

Open access
Hennig, Juergen, Weigel, Matthias, Scheffler, Klaus·2003·Magnetic Resonance in Medicine

Abstract

A variation of the rapid acquisition with relaxation enhancement (RARE) sequence (also called turbo spin‐echo (TSE) or fast spin‐echo (FSE)) is presented. This technique uses variable flip angles along the echo train such that magnetization is initially prepared into the static pseudo steady state (PSS) for a low refocusing flip angle (α < 180°). It is shown that after such a preparation, magnetization will always stay very close to the static PSS even after significant variation of the subsequent refocusing flip angles. This allows the design of TSE sequences in which high refocusing flip angles yielding 100% of the attainable signal are applied only for the important echoes encoding for the center of k‐space. It is demonstrated that a reduction of the RF power (RFP) by a factor of 2.5–6 can be achieved without any loss in signal intensity. The contribution of stimulated‐echo pathways leads to a reduction of the effective TE by a factor ft, which for typical implementations is on the order of 0.5–0.8. This allows the use of longer echo readout times, and thus longer echo trains, for acquiring images with a given T2 contrast. Magn Reson Med 49:527–535, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10391

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Hennig, J., Weigel, M., & Scheffler, K.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-03
Volume
49
Issue
3
Pages
527-535
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2008067649
Cited by
244
References
0
FWCI
7.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS). https://app.cochat.ai/papers/10.1002/mrm.10391
The paper
Hennig, J., Weigel, M., & Scheffler, K. (2003). Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS). Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10391

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.