Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 517

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast

Gold, Garry E., Han, Eric, Stainsby, Jeff, Wright, Graham, Brittain, Jean, Beaulieu, Christopher·2004·American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of our study was to measure relaxation times in musculoskeletal tissues at 1.5 and 3.0 T to optimize musculoskeletal MRI methods at 3.0 T. MATERIALS AND METHODS: In the knees of five healthy volunteers, we measured the T1 and T2 relaxation times of cartilage, synovial fluid, muscle, marrow, and fat at 1.5 and 3.0 T. The T1 relaxation times were measured using a spiral Look-Locker sequence with eight samples along the T1 recovery curve. The T2 relaxation times were measured using a spiral T2 preparation sequence with six echoes. Accuracy and repeatability of the T1 and T2 measurement sequences were verified in phantoms. RESULTS: T1 relaxation times in cartilage, muscle, synovial fluid, marrow, and subcutaneous fat at 3.0 T were consistently higher than those measured at 1.5 T. Measured T2 relaxation times were reduced at 3.0 T compared with 1.5 T. Relaxation time measurements in vivo were verified using calculated and measured signal-to-noise results. Relaxation times were used to develop a high-resolution protocol for T2-weighted imaging of the knee at 3.0 T. CONCLUSION: MRI at 3.0 T can improve resolution and speed in musculoskeletal imaging; however, interactions between field strength and relaxation times need to be considered for optimal image contrast and signal-to-noise ratio. Scanning can be performed in shorter times at 3.0 T using single-average acquisitions. Efficient higher-resolution imaging at 3.0 T can be done by increasing the TR to account for increased T1 relaxation times and acquiring thinner slices than at 1.5 T.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.183.2.1830343

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 517

Metadata

Authors
Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C.
Venue
American Journal of Roentgenology
Published
2004-08
Volume
183
Issue
2
Pages
343-351
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2136247797
Cited by
517
References
20
FWCI
22.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast. https://app.cochat.ai/papers/10.2214/ajr.183.2.1830343
The paper
Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C. (2004). Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast. American Journal of Roentgenology. https://doi.org/10.2214/ajr.183.2.1830343

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.