The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Abstract
OBJECTIVE: The purpose of our study was to measure relaxation times in musculoskeletal tissues at 1.5 and 3.0 T to optimize musculoskeletal MRI methods at 3.0 T. MATERIALS AND METHODS: In the knees of five healthy volunteers, we measured the T1 and T2 relaxation times of cartilage, synovial fluid, muscle, marrow, and fat at 1.5 and 3.0 T. The T1 relaxation times were measured using a spiral Look-Locker sequence with eight samples along the T1 recovery curve. The T2 relaxation times were measured using a spiral T2 preparation sequence with six echoes. Accuracy and repeatability of the T1 and T2 measurement sequences were verified in phantoms. RESULTS: T1 relaxation times in cartilage, muscle, synovial fluid, marrow, and subcutaneous fat at 3.0 T were consistently higher than those measured at 1.5 T. Measured T2 relaxation times were reduced at 3.0 T compared with 1.5 T. Relaxation time measurements in vivo were verified using calculated and measured signal-to-noise results. Relaxation times were used to develop a high-resolution protocol for T2-weighted imaging of the knee at 3.0 T. CONCLUSION: MRI at 3.0 T can improve resolution and speed in musculoskeletal imaging; however, interactions between field strength and relaxation times need to be considered for optimal image contrast and signal-to-noise ratio. Scanning can be performed in shorter times at 3.0 T using single-average acquisitions. Efficient higher-resolution imaging at 3.0 T can be done by increasing the TR to account for increased T1 relaxation times and acquiring thinner slices than at 1.5 T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
POTTER, H. G., LINKLATER, J. M., ALLEN, A. A., HANNAFIN, J. A., & HAAS, S. B. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199809000-00005 · Cited by 590
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Self-citationAnisotropy of NMR properties of tissues
Henkelman, R. M., Stanisz, G. J., Kim, J. K., & Bronskill, M. J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320508 · Cited by 424
Mosher, T. J., Dardzinski, B. J., & Smith, M. B. (2000) · Radiology · doi:10.1148/radiology.214.1.r00ja15259 · Cited by 390
Radiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · Cited by 343
Spatial variation in cartilage T2 of the knee
Smith, H. E., Mosher, T. J., Dardzinski, B. J., Collins, B. G., Collins, C. M., Yang, Q. X., Schmithorst, V. J., & Smith, M. B. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1150 · Cited by 288
Collins, C. M., & Smith, M. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1091 · Cited by 260
Hennig, J., Weigel, M., & Scheffler, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10391 · Cited by 244
Cited by
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
Van Steenkiste, G., Poot, D. H. J., Jeurissen, B., den Dekker, A. J., Vanhevel, F., Parizel, P. M., & Sijbers, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26262 · Cited by 20
Metadata
- Authors
- Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2004-08
- Volume
- 183
- Issue
- 2
- Pages
- 343-351
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2136247797
- Cited by
- 517
- References
- 20
- FWCI
- 22.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast. https://app.cochat.ai/papers/10.2214/ajr.183.2.1830343
- The paper
- Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C. (2004). Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast. American Journal of Roentgenology. https://doi.org/10.2214/ajr.183.2.1830343
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.