Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI): Methodology and comparison with blood oxygen level‐dependent (BOLD) MRI
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This work presents a methodology for obtaining quantitative oxygen concentration images in the tumor‐bearing legs of living C3H mice. The method uses high‐resolution electron paramagnetic resonance imaging (EPRI). Enabling aspects of the methodology include the use of injectable, narrow, single‐line triaryl methyl spin probes and an accurate model of overmodulated spectra. Both of these increase the signal‐to‐noise ratio (SNR), resulting in high resolution in space (1 mm)3 and oxygen concentrations (∼3 torr). Thresholding at 15% the maximum spectral amplitude gives leg/tumor shapes that reproduce those in photographs. The EPRI appears to give reasonable oxygen partial pressures, showing hypoxia (∼0–6 torr, 0–10 3 Pa) in many of the tumor voxels. EPRI was able to detect statistically significant changes in oxygen concentrations in the tumor with administration of carbogen, although the changes were not increased uniformly. As a demonstration of the method, EPRI was compared with nearly concurrent (same anesthesia) T/blood oxygen level‐dependent (BOLD) MRI. There was a good spatial correlation between EPRI and MRI. Homogeneous and heterogeneous T/BOLD MRI correlated well with the quantitative EPRI. This work demonstrates the potential for EPRI to display, at high spatial resolution, quantitative oxygen tension changes in the physiologic response to environmental changes. Magn Reson Med 49:682–691, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Hypoxia-mediated selection of cells with diminished apoptotic potential in solid tumours
Graeber, T. G., Osmanian, C., Jacks, T., Housman, D. E., Koch, C. J., Lowe, S. W., & Giaccia, A. J. (1996) · Nature · doi:10.1038/379088a0 · Cited by 2,300 · cited 1×
“Lack of oxygen in a tissue (hypoxia) appears to predispose its surviving cells to mutagenesis, thereby increasing the likelihood that a malignant state will develop (3).”
Background
Cited by
Krohn, K. A., Link, J. M., & Mason, R. P. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045914 · Cited by 506
“Two primary approaches are used: direct injection of char crystals (180,181), phthalocyanine (182), or India ink (183) into tissue, most commonly tumors, although studies have also been reported of injection into brain, heart, and skeletal muscle; or intravenous infusion of water-soluble agents, which disseminate thro…”
BackgroundMethodNovel particulate spin probe for targeted determination of oxygen in cells and tissues
Pandian, R. P., Parinandi, N. L., Ilangovan, G., Zweier, J. L., & Kuppusamy, P. (2003) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(03)00496-9 · Cited by 150
Serganova, I., Humm, J., Ling, C., & Blasberg, R. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-0517 · Cited by 50
Metadata
- Authors
- Elas, M., Williams, B. B., Parasca, A., Mailer, C., Pelizzari, C. A., Lewis, M. A., River, J. N., Karczmar, G. S., Barth, E. D., & Halpern, H. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-03-18
- Volume
- 49
- Issue
- 4
- Pages
- 682-691
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2006581202
- Cited by
- 194
- References
- 2
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI): Methodology and comparison with blood oxygen level‐dependent (BOLD) MRI. https://app.cochat.ai/papers/10.1002/mrm.10408
- The paper
- Elas, M., Williams, B. B., Parasca, A., Mailer, C., Pelizzari, C. A., Lewis, M. A., River, J. N., Karczmar, G. S., Barth, E. D., & Halpern, H. J. (2003). Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI): Methodology and comparison with blood oxygen level‐dependent (BOLD) MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.