Method for quantitative imaging of the macromolecular 1H fraction in tissues
Open accessThe DOI matches its Crossref record.
Abstract
A new method was developed for mapping the relative density of the macromolecular protons involved in magnetization transfer (MT). This method employs a stimulated echo preparation scheme in order to modulate the phase distribution within a spin ensemble. This labeled spin ensemble is then used as an intrinsic indicator, which is diluted due to magnetization exchange with macromolecular protons. A pulse sequence is presented which compensates for longitudinal relaxation, allows observation of the dilution effect only, and provides for calculation of parameter maps using indicator dilution theory. Compared to other quantitative MT techniques, neither additional relaxation time measurements nor knowledge regarding the lineshape of the macromolecular proton pool are required. Moreover, the inherent low specific absorption rate and the low sensitivity for B1 errors make this method favorable in a clinical setting. This sequence was used to measure the macromolecular proton density in cross‐linked bovine serum albumin. Using a navigated echo planar readout, the sequence was also employed to visualize the macromolecular content of human brain in vivo. Magn Reson Med 49:864–871, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
MRI in multiple sclerosis: current status and future prospects
Bakshi, R., Thompson, A. J., Rocca, M. A., Pelletier, D., Dousset, V., Barkhof, F., Inglese, M., Guttmann, C. R., Horsfield, M. A., & Filippi, M. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70137-6 · Cited by 348
Magnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334
Yarnykh, V. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23224 · Cited by 162
“(29) requires single-slice two-dimensional acquisition, which translates into a long scan time if whole-brain coverage is needed.”
BackgroundMethodGochberg, D. F., & Gore, J. C. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21143 · Cited by 159
Metadata
- Authors
- Ropele, S., Seifert, T., Enzinger, C., & Fazekas, F.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-04-15
- Volume
- 49
- Issue
- 5
- Pages
- 864-871
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2070259348
- Cited by
- 64
- References
- 0
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method for quantitative imaging of the macromolecular 1H fraction in tissues. https://app.cochat.ai/papers/10.1002/mrm.10427
- The paper
- Ropele, S., Seifert, T., Enzinger, C., & Fazekas, F. (2003). Method for quantitative imaging of the macromolecular 1H fraction in tissues. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10427
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.